‐
2
‐
z
Z
‐
Wave
Configuration
Association
Groups
The
product
supports
4
association
groups.
Each
group
(#2~#4)
supports
associated
8
devices
maximum
except
group
#1
support
associated
1
device
only.
i.
Group
#1
is
assigned
to
send
unsolicited
report
lifeline
status,
including
central
scene
report,
notification
alarm
report,
battery
report,
factory
reset
locally
report
etc.
ii.
Group
#2
assigned
to
send
Basic
Set
Off/Binary
Switch
Off/Multilevel
Start
Change
Down/Door
Lock
Secure
Command
control
associated
devices
corresponding
to
the
“off”
key
operation,
including
key
press
1
times.
iii.
Group
#3
assigned
to
send
Basic
Set
On/Binary
Switch
On/Multilevel
Start
Change
Up/Door
Lock
Unsecure
Command
control
associated
devices
corresponding
to
the
“on”
key
operation,
including
key
press
1
times.
iv.
Group
#4
assigned
to
send
Stop
Multilevel
Change
Command
control
associated
devices
corresponding
to
the
“stop”
key
operation,
including
key
press
1
times.
The
production
supports
setting
each
group
of
association
device
from
GUI
of
the
master
controller,
or
setting
group
#2~#4
association
device
together
by
key
‐
fob
itself
locally.
Please
refer
to
the
master
controller’s
operating
manual
to
add
an
association
device
and
specify
to
which
group
and
what
devices
are
to
be
associated.
The
production
supports
send
difference
command
to
group
#2~#4
associated
device
base
on
device
type
when
it
was
associated
by
key
‐
fob
itself
locally,
or
only
send
Basic
On/Off
command
if
it
was
associated
from
GUI
of
the
master
controller.
Secure
vs
no
‐
Secure
add
to
Z
‐
Wave
Network
The
production
is
a
security
enabled
Z
‐
wave
Plus
production,
implements
Z
‐
Wave
Application
Security
Layer
in
accordance
with
Z
‐
Wave
protocol.
This
device
must
be
used
in
conjunction
with
a
Security
Enabled
Z
‐
Wave
Controller
in
order
to
fully
implemented
secure
functions.
Even
though
the
functionality
and
support
command
class
are
same
when
included
as
secure
or
no
‐
secure
node.
But
only
following
command
class
are
supported
no
‐
secure
access
if
it
was
added
to
Z
‐
Wave
network
as
secure:
COMMAND_CLASS_ZWAVEPLUS_INFO
COMMAND_CLASS_POWERLEVEL,
Wakeup
key
‐
fob
manually
for
Z
‐
Wave
configuration
The
product
is
in
battery
power,
you
can
set
up
the
wake
up
time
based
in
seconds.
At
each
wake
up,
the
product
communicates
with
the
master
controller
to
updates
parameters
settings
if
necessary,
e.g.
receive
the
association
group
setting.
The
product
will
wake
up
at
defined
time
interval
and
will
ALWAYS
try
to
communicate
with
the
master
controller.
Longer
time
interval
means
less
frequent
communication
and
thus
a
longer
battery
life.
The
product
default
wakeup
interval
is
86400
seconds.
User
can
operate
inclusion/exclusion
process
in
order
to
trigger
product
wakeup
manually,
it
will
keeps
in
wakeup
state
for
30
seconds
without
initial
wakeup
parameter
setting
and
will
keeps
in
wakeup
state
for
10
seconds
after
initial
wakeup
parameter.
Application
Requirement
Reject
Since
the
product
is
configuration
with
push
mode
of
alarm
report,
it
will
reply
Application
Requirement
Reject
to
the
device
that
attempts
change
alarm
report
push
mode
to
pulling
mode.
Notification
Type
and
Event