Steam Generator
Control
Master
Steam Generator
DIP SW
3 = OFF
DIP SW
3 = ON
2 = OFF
1 = OFF
DIP SW
3 = ON
2 = ON
1 = OFF
Slave 1
Steam Generator
Slave 2
Steam Generator
Slave 3 Slave 4
RJ12 Cable
Standby
Duration
Mode
Switch
6
Switch
7
Switch
8
4h
0
0
6h
0
0
12h
0
1
18h
0
1
0
1
0
1
Unlimited
1
0
0
4h
1
0
1
4h
1
1
0
4h
1
1
1
Slave
No.
Switch
1
Switch
2
1
0
0
2
0
1
3
1
0
4
1
1
Session
Time
Switch
2
Switch
3
Switch
4
10min
0
0
15min
0
0
20min
0
0
30min
0
0
0
0
1
1
45min
0
1
0
1h
0
1
0
2h
0
1
1
4h
0
1
1
Switch
5
0
1
0
1
0
1
0
1
6h
1
0
0
0
8h
1
0
0
1
12h
1
0
1
0
18h
1
0
1
1
Unlimited
1
1
0
0
10min
1
1
0
1
10min
1
1
1
0
10min
1
1
1
1
Dipswitch
No.:
Function
On
Off
8
Cabin Light
7
6
5
4
3
2
1
30-55°C
Dimmer option
enabled
Dimmer option
disabled
Present
Present
Connected
Yes
30-50°C
Not Present
Not Present
Not Connected
No
Fan
Scent Pump
Auto Drain
Temperature range
Slave Unit
Slave Number
Slave Number
DIMMER
FAN
SCEN
T PUMP
DRAIN
TEMP
SL
AVE
S
TANDBY
SESSION
1
=
=
ON
OFF
0
STAND-BY ON/OFF
DIP No.
Function
8
Standby mode duration
7
6
5
4
3
2
1
Standby mode duration
Standby mode duration
Maximum session time
Maximum session time
Maximum session time
Maximum session time
Disable standby mode
/ Enable standby mode
Temperature sensor 1
not connected.
Temperature sensor 1
short circuit.
Temperature sensor 2
not connected.
Temperature sensor 2
short circuit.
Temperature fuse defect.
E1
E2
E3
E4
E5
Check the wire between the sensor and the
control unit.
If there is no problem with the wires and they
are correctly installed, check the sensor.
If no problem can be found, contact the retailer.
Check the wire between the fuse and the control
unit. Fuse has probably overheated. The reason
for it needs to be discovered before using the
steam generator again. A new fuse is needed.
If no problem can be found, contact the retailer.
steam Generator series Connection
Troubleshooting
If an error occurs, the steam generator will be switched off. There will be a
warning beep to alarm the user every 2 seconds. The code for the error will be
displayed blinking in the control panel, see the table below.
Please note, only a qualified electrician or maintenance personnel are allowed to
make the service operations and repairs!
If an error occurs in one of the slave units, error message is followed by slave
number. For example: E1 -> S2 -> E1 ->S2... Pressing ON/OFF button disables
the slave and rest of the generators can operate normally.
Possible errors are:
Code
Problem
Solution