![Sawo STN-120-3 Скачать руководство пользователя страница 10](http://html1.mh-extra.com/html/sawo/stn-120-3/stn-120-3_manual_1204550010.webp)
ENGLISH
10
min.
300mm
min.150mm
240mm
380mm
min.100mm
STEAM R
OOM
min.150mm
WALL
WALL
Steam Generator
Screw to the wall.
Interchangeable
bracket.
FLOOR
CEILING
Temperature sensor
Demand
Button
Water source
Water Filter / Softener
Water inlet
Power supply
Drain
Steam Head
Over
Pressure
Autodrain
Dosing Nozzle
Steam
generator
Scent Pump
Control unit
Steam Line
2.
level probe cleaning
c. Disconnect steam generator from main supply before opening generator’s covers.
Only licensed electrician or professional maintenance person can open covers and do
cleaning.
d. Use adjustable wrench to deattach 3 wires from level probe. Make sure that when
connecting wires back, wires are connected to right probes.
e. Use adjustable wrench to remove level probe. Clean tip of the pins from impurities
using sandpaper. Don’t damage plastic coating on pins. If coating is damaged, replace
level probe. Tighten level probe by hands and use adjustable wrench only for final
tightening.
3.
Tank cleaning
easy way of cleaning the tank.
a. Disconnect steam generator from main supply before opening generator’s covers.
Only licenced electrician or professional maintenance person can open covers and do
cleaning.
b. Clean level probe as stated in 2.a to 2.b.
c. Remove temperature fuse and tank temperature sensor from terminal block.
d. Remove the cassette where the heating elements are attached and clean deposits
from the element.
e. Remove deposits from bottom and sides of the tank. Open bottom plug to wash away
deposits. Don’t use autodrain valve since big particles can block autodrain valve.
f.
Attach bottom plug and use teflon pipe seal if needed.
g. Attach heating elements. Make sure that temperature fuse and tank tempesensor are
on the top of heating element. Inserting heating element upside down will prevent
the temperature fuse from working.
WaRnInG!
Do not overtighten the nuts that hold
heating element cassette. Damaged