![Sawo STN-120-3 Скачать руководство пользователя страница 12](http://html1.mh-extra.com/html/sawo/stn-120-3/stn-120-3_manual_1204550012.webp)
ENGLISH
12
Water Filter /
Softener
3/4” BSP
Water Inlet
Power
Switch
Power
Switch
Thread:
1” BSP
485mm
560mm
Steam
Outlet Valve
Automatic
Drain
Thread:
1” BSP
485mm
560mm
Steam
Outlet Valve
Automatic
Drain
3/4” BSP
Water Inlet
noTe!
If facing the wall there should be
at least 100mm allowance.
noTe!
If facing the wall there should be
at least 100mm allowance.
noTe!
Refer to Technical Data for specifications.
steam Generator
3,0 kW | 3,5 kW | 4,0 kW | 4,5 kW | 5,0 kW
4,5 kW | 5,0 kW | 6,0 kW |7,5 kW
9,0 kW | 12,0 kW | 15,0 kW
Side view
showing element
access panel
Water supply
Provide a shut off valve on the water source for the steam generator. Turn off the inlet
water line before installing the unit. Refer to the water filter’s manual for the pressure
requirement when installing. Maximum water pressure without water filter/softener is 8
bar. The water flow range must be at minimum of 4 liters per minute. Water softener is
recommend to use.
Water Pressure
The water pressure required for the STP steam generators is 2-8 bar or 30-120psi. Below
or above the pressure requirement may lead to damage or malfunction of the water inlet.
Connecting Water filter and softener
For illustrative purposes only.