Terminal Connection of Demand button
(optional)
Before installation make sure that the mains is
disconnected from the generator by turning off the
circuit breaker.
1. Open the top cover of the generator.
2. Guide the cable through cable lead-in on the side
of the generator.
3. Connect the wires to their designated places in
the terminal block.
4. If the demand button has light connect the light
wire on the “ILL” labeled terminal.
Make sure that polarity is right “ILL” output is +12VDC and 20mA.
If you have optional
dimmer in steam
generator, make sure that
the ligths are dimmable
before connecting. Steam
generator uses phase
control to regulate power
for lighting.
light
fan
(Optional)
scent Pump
(Optional)
Max. 100W