![Sawo STN-120-3 Скачать руководство пользователя страница 18](http://html1.mh-extra.com/html/sawo/stn-120-3/stn-120-3_manual_1204550018.webp)
ENGLISH
18
A
B
160 mm
84 mm
C
Installing the Temperature sensor
before installation main supply of the generator must be switch off from the
circuit braker.
The temperature sensor comes along with the SAWO steam generator. It is recommended
to use only Sawo temperature sensor with Sawo generator as it may otherwise not function
correctly.Temperature sensor wiring should not be routed near power cables or hot areas
as it may cause electronic interference or damage to the wires.
The sensor has an integrated 9-meter cable. If longer cable is
needed use 2 x 0,5 mm2 to 2 x 1,0 mm2 cable for extension.
1. The temperature sensor has to be installed:
Height 1,2-1,5 meters above the floor away from
the steam head so that the steam will not hit the
sensor directly.
2. A 25mm hole is required to insert the temperature
sensor. Do not create bigger or smaller hole. Clean
the hole before inserting the sensor.
3. Make a hole in the cable lead-in on the side of the
generator to pull the cable through. Connect the
cable in the terminal block marked as “TEMP”. See
figure 2.
4. Insert the temperature sensor through the steam
room wall. Do not apply staples or other material
that may damage the cable.
5. Apply silicone sealant on the hole in the wall to
create a moisture seal (Fig. 4). Make sure that
there is no trace of silicone on the sensor as it may
interfere its reading.
Fig. 1
Temperature
Sensor
Terminal Block
TEMP
Ø 25mm
Push sensor
head to lock
Silicone Sealant
Wall
Cable
Push to the
wall to stick
Fig. 2
SAWO Steam Generator
(shown with cover removed)
Fig. 3
Fig. 4
Fig. 5
For illustrative purposes only.