7
Step 3.
(Fig. 14 & 15) Receiver to House
Supply Wires Electrical Connections:
Connect the black (hot) wire from the
ceiling to the black wire marked "AC in L"
from the receiver. Connect the white
(neutral) wire from the ceiling to the white
wire marked "AC in N" from the Receiver.
Secure the wire connections with the
plastic wire nuts provided.
Step 4.
(Fig. 14 & 15) If your outlet box has
a ground wire (green or bare copper)
connect it to the fan ground wires;
otherwise connect the hanging bracket
ground wire to the mounting bracket.
Secure the wire connection with a plastic
nut provided. After connecting the wires,
spread them apart so that the green and
white wires are on one side of the outlet
box and black and blue wires are on the
other side. Carefully tuck the wire
connections up into the outlet box.
Note:
Fan must be installed at a maximum
distance of 30 feet from the transmitting
unit for proper signal transmission
between the transmitting unit and the
fan's receiving unit.
Figure 14
White (neutral)
White (neutral)
Green or bare
copper (ground)
White ("AC IN N")
White ("to motor N")
Ground
(green)
(Connect to
ground wire on
hanger bracket
if no house
ground wire
exists.)
Outlet box
Black (hot)
Black ("AC IN L")
Black ("to motor L")
Receiver
Blue (for light)
Blue (for light)
Black (motor)
Figure 15
INPUT
AC120V
AC SUPPLY
White
White
White
Blue
Black
Black
Black
Black
Black
Black
Black
Wall
transmitter
Ground
Ground
Green
Green
White
Blue
Black
Fan