SP-5 Service Manual
2
STOP!
ELECTRICAL REQUIREMENTS
This equipment is constructed of the very finest materials attainable. In order to attain maximum efficiency and
reliability from this equipment, please follow guidelines below concerning electrical hook-up and site preparation.
In addition to its glass and metal components, this unit contains various microprocessors and electrical
components that are sensitive to harsh environments and electrical static, spikes, voltage sags, etc., similar to
any computerized device. Outlined below are areas to be considered when performing installation.
1. DEDICATED LINE – No other equipment may be connected to this line.
2. CORRECT VOLTAGE – The voltage is specified on the data plate. This is not a dual voltage unit. Check
voltage with a meter to ascertain actual voltage (i.e. 208V or 240V).
3. SUPPLY CONNECTION WIRE GUAGE:
1 Phase – No. 8 AWG
3 Phase – No. 10AWG
Wire to be suitable for at least 60° C
4. TERMINAL
BLOCK
CONFIGURATION:
5. Never block air intake on the bottom or exhaust from left side louvers.
6. Legs must be secured and used to level the equipment.
7. No obstructions under, on top, or around the unit to restrict air flow or cause unsafe conditions.
MECHANICAL DIMENSIONS
Unit Weight – 216 lbs. (98 kg.)
KEY
1. Switch with program selector
2. Display Window
3. Electrical Connection
4.
Adjustable
Feet
5.
Rotor
Unit
6. Double Spits, 5 pcs.
7. Fat Tray, pull and tilt for emptying. The tray is removable.
!
DO NOT ATTEMPT INSTALLATION UNTIL YOU HAVE READ THE FOLLOWING
INFORMATION!
!
CAUTION
!