SP-5 Service Manual
12
Figure 16
Figure 18
Figure 17
LOCK HANDLE
Disassembly Instructions:
1. Disconnect main voltage.
2. Remove
the
screws.
3. Remove the Lock Handle.
Assembly Instructions:
1. Assemble in reverse order according to steps 1-
3 above.
NOTE: Use lock liquid on the screws.
LOCK CASTING
Adjusting Instructions:
1. Disconnect main voltage.
NOTE: Before adjusting the lock casting, the door
should be adjusted to 100 +/- 1mm (3.94”).
2. Loosen the screws in the casting so the casting
can be adjusted.
3. Adjust the casting so that it lines up with the
center of the hole in the handle and the vertical
measurement will be in accord with what is
shown in Figure 17.
4. Re-tighten the screws.
5. Adjust the lock wedge to make the gap between
the roof and the door roof parallel.
IR – LAMPS (#15275)
Disassembly Instructions:
1. Disconnect the main voltage.
2. Remove the door roof.
3. Remove the lids over the lamps.
4. Remove the nuts on the connector cable screws.
Assembly Instructions:
1. DO NOT touch the IR-Lamps with your fingers.
2. Trim the connector strips to size.
3. Assemble in reverse order according to steps 1-
4 above.
NOTE: Make sure you don’t apply torque to the
connector strip. Check to make sure the lamp is not
rigidly mounted. Remove the protective cover paper.
REQUIRED PARTS
QTY
POSITION
Quartz Tube
1
1