SP-5 Service Manual
16
Temp
°F
0 10 20 30 40 50 60 70 80 90
Ω
°F
0
921.190 942.790 964.350 985.880 1007.368 1028.814 1050.224 1071.594 1092.927 1114.221
2.14
100
1335.476 1156.693 1177.872 1199.011 1220.113 1241.176
1262.200
1283.186
1304.133 1325.042
2.11
200
1345.913 1366.744 1387.538 1408.293 1429.009 1449.687
1470.326
1490.927
1511.489 1532.013
2.07
300
1552.498 1572.945 1593.953 1613.723 1634.054 1654.347
1674.601
1894.817
1714.994 1735.133
2.03
400
1755.233 1775.295 1795.318 1815.303 1835.249 1855.157
1875.026
1894.857
1914.649 1934.402
1.99
500
1954.117 1973.794 1993.432 2013.032 2032.593 2052.116
2071.600
2091.045
2110.452 2129.821
1.95
600
2149.151 2168.443 2187.698 2206.910 2226.086 2245.224
2264.323
2283.383
2302.405 2321.389
1.91
700
2340.334 2359.240 2378.108 2396.938 2415.729 2434.481
2453.195
2471.871
2490.508 2509.106
1.88
800
2527.686 2546.187 2564.670 2583.115 2601.521 2619.886
2638.217
2656.507
2674.759 2692.973
1.84
900
2711.147 2729.264 2747.382 2785.441 2783.462 2801.444
2637.293
2837.293
2855.180 2872.986
1.80
1000
2890.778
- - - - -
-
-
- -
-
PT-500 TEMPERATURE / RESISTANCE TABLES
FOR REFERENCE ONLY
Ohm/°F = Value @ Center of 100°F Span
TEMP °F
0
25
50
75
100 575
603
625
650
200 685
700
732
760
300 780
810
841
863
400 892
905
941
965
500 988
- - -
#19390 ELECTRONIC TIME / TEMPERATURE CONTROL
CONTROL ERROR CODES
Error codes are provided to aid in determining the nature of common oven failures and to inform the user of
possible safety or performance problems. Each error has an associated code number that is displayed in the
time digits when the error occurs. The control also sounds a series of attention tones. The control must be
powered down to clear the failure mode.
If a service call is received, sighting any of the following “Error Codes,” please instruct the customer to turn the
oven off and wait for service.
Prior to replacing any of these parts, all the wiring and voltages to the controller should be verified.
ERROR CODE #
ACTION TO BE TAKEN
F1
Replace the T/T Controller (#19390)
F2
Oven temperature has exceeded 551°. Check actual oven temperature and resistance
of RTD Sensor and replace if necessary.
F3
The RTD Sensor (#15856) may have an open circuit. Check the resistance and
replace if necessary. If F3 still appears, replace controller.
F4
The RTD Sensor (#15856) may have a short circuit. Check the resistance and replace
if necessary.
F5
Replace the T/T Controller (#19390)
F6
Replace the T/T Controller (#19390)
F7
Replace the T/T Controller (#19390)
#15250 – PT500, RTD
(used prior to S/N SP0002237)
#15856 – RTD, 1000 OHM
(Starting with S/N SP0002237)