background image

IMPORTANT 

The device should be installed by qualified personnel. 

 

Prior to installation, please read carefully this manual. 

 

Changes,  modifications  or  repairs  not  authorized  by  the  manufacturer  shall  void  your  rights 
under the warranty. 
 
The rating plate of the device is located on the enclosure base. 

 
 
 
 
 
 
 
 
 
 

SATEL aims to continually improve the quality of its products, which may result in changes in 

their technical specifications and software. Current information about the changes being 

introduced is available on our website. 

Please visit us at: 

http://www.satel.eu 

 
 
 
 
 
 
 

Hereby, SATEL sp. z o.o. declares that the radio equipment type MPD-300 is in 

compliance with Directive 2014/53/EU. The full text of the EU declaration of conformity 

is available at the following internet address: www.satel.eu/ce 

 
 
 
 
 
The following symbols may be used in this manual: 

 

-  note; 

  -  caution. 

 

Содержание micra MPD-300

Страница 1: ...MPD 300 Wireless passive infrared detector Firmware version 2 00 mpd 300_en 06 20 SATEL sp z o o ul Budowlanych 66 80 298 Gda sk POLAND tel 48 58 320 94 00 www satel eu...

Страница 2: ...improve the quality of its products which may result in changes in their technical specifications and software Current information about the changes being introduced is available on our website Pleas...

Страница 3: ...ption 2 Radio communication 2 Alarms 2 Operating modes 2 Test mode 2 LED 3 Supervision of motion detection system 3 Battery status control 3 Electronics board 3 3 Selecting a mounting location 4 4 Ins...

Страница 4: ...the detector sends information about its state periodical transmission Additional radio transmissions take place as a result of alarm Alarms The detector will report alarm after detecting a motion in...

Страница 5: ...an alarm during periodical transmission The alarm will keep going until the fault is cleared long violation Battery status control When the battery voltage is below 2 75 V information about low batter...

Страница 6: ...ED indicator tamper switch activated by detector removal from the back tamper unit tamper switch activated by cover removal PIR sensor dual element pyrosensor scale for positioning of PIR sensor again...

Страница 7: ...The used batteries must not be discarded but should be disposed of in accordance with the existing rules for environment protection 1 Remove the front cover Fig 7 2 Configure the detector using the ju...

Страница 8: ...he mounting screw hole facilitates positioning of the electronics board depending on the detector installation height Fig 12 12 Close and open the tamper switch that detects the cover removal to enabl...

Страница 9: ...n 55 A Maximum current consumption 58 mA Detectable speed 0 3 3 m s Warm up period 15 s Recommended installation height 2 4 m Coverage area normal sensitivity 14 m x 12 m 86 high sensitivity 16 m x 18...