6
MPD-300
SATEL
for concrete, brick, etc. For other types of surface (drywall, styrofoam), use the
appropriately selected wall plugs.
If the detector is to be pet immune, do not mount it on the bracket.
10. Screw the enclosure base to the back tamper unit (Fig. 11).
11. Fasten the electronics board. The scale next to the mounting screw hole facilitates
positioning of the electronics board, depending on the detector installation height
(Fig. 12).
12. Close and open the tamper switch that detects the cover removal to enable the test mode.
13. Replace the cover.
14. Check if moving around within the detector coverage area will make the LED to light up.
Fig. 5 and 6 show the coverage area of a detector mounted at a height of 2.4 m (Fig. 5
–
normal sensitivity, Fig. 6
– high sensitivity; you can set the sensitivity using the jumper –
Fig. 4).