SATEL INTEGRA
Plus
21
The function is unavailable, if the time synchronization is running. Automatic time
synchronization takes place every day at 05:30 and after the control panel restart.
Service access
– available to the master user (administrator). Allows to program the time
period of installer access to the alarm system. The time is programmed in hours.
Programming the value 0 means the installer will have no access.
Open door
– allows to unlock the door controlled by the alarm system (modules executing
the access control functions) or activate the 101. C
ARD READ
–
EXPANDER
type outputs.
Outputs control
– allow to control the devices connected to the MONO
SWITCH
, BI
SWITCH
,
R
EMOTE SWITCH
, S
HUTTER UP
and S
HUTTER DOWN
type outputs (see: “Outputs control”
p. 34).
Service mode
– available to the installer. Initiates the service mode.
Take SM over
– available to the installer. If the service mode has been initiated from another
keypad, it can be “taken over”, i.e. the service menu can be displayed on the keypad, on
which the T
AKE
SM
OVER
function has been started.
Downloading
– the following functions are available in the submenu
Start DWNL-RS
– available to the installer. Enables the control panel to be programmed
locally by means of the DLOADX
program.
Finish DWNL-RS
– available to the installer. Ends the local programming of control panel.
Start DWNL-MOD.
– enables remote programming through an external modem (analog,
GSM or ISDN) by means of the DLOADX program.
Start DWNL-TEL
– enables remote programming through the built-in 300 bps modem,
using the DLOADX program.
ETHM-1 – DLOADX
– enables remote programming through the Ethernet (TCP/IP) by
means of the DLOADX program. The ETHM-1 (firmware version 1.03 or newer) /
ETHM-1 Plus module must be connected to the control panel.
ETHM-1 – GUARDX
– enables remote operation and administration through the Ethernet
(TCP/IP) by means of the GUARDX program. The ETHM-1 (firmware version 1.03 or
newer) / ETHM-1 Plus module must be connected to the control panel).
5.4 Arming
This section describes the operations that must be carried out by the user from the keypad in
order to initiate the arming procedure. The arming procedure is ended at the running out of
the exit delay time (if the procedure is ended successfully, the system becomes armed – see
also “Failure of arming procedure” p. 23). If the exit delay time is 0, the system becomes
armed instantly.
The installer can configure the alarm system so that the arming functions will not be
available after tamper. A message on the display will indicate that the user must call
for service. The arming functions will not be available until the service code is entered
and confirmed with the key.
5.4.1 Full arming without partition selection
The arming without partition selection is possible when none of the partitions to which the
user has access is armed and the keypad is not signaling any alarm.
1. Enter the code and confirm with the key.
2. When the A
RM ALL
function is displayed, press the key. The arming procedure will be
initiated in all partitions which are accessible to the user and are operated by the keypad.