26 User
Manual
SATEL
Normal
– basic type of user.
One-time
[Single] – the user will get one-time access.
Renewable
[Time renewable] – the user has access to the system for a defined period of
time. The user validity time should be defined. Before the validity time expires, the control
panel will prompt the user to change the code. After the code has been changed, the
validity time will run from the beginning.
Temporary
[Time not renew.] – the user has access to the system for a defined period of
time. The user validity time should be defined. After the validity time expires, the user will
have no access to the system.
Duress
– code to be used in hold-up and duress situations. Use it to trigger a silent alarm
and send the event code to the monitoring station.
“Mono” output operating
[Mono outputs] – code for control of the MONO
SWITCH
type
outputs.
“Bi” output operating
[Bi outputs] – code for control of the BI
SWITCH
type outputs.
Blocking partition
[Part.temp.block.] – the code enables access to the armed partitions.
Using the code will block the armed partition(s) (the partition zones will not trigger the
burglary alarm). The blocking time is defined individually for each user within the range
from 1 to 109 minutes. If, however, the time of bypassing for guard round is defined for the
partition and its duration is longer, the blocking will last longer.
Cash machine zones bypassing
[Acces.to cash m.] – the code to be used to unblock
access to the cash dispenser (the 24H
C
ASH MACHINE
type zones will be temporarily
bypassed in the partition).
Guard
– using this code means having made the round (additionally, it can result in the
partition being temporarily bypassed for the duration of guard round). The installer defines
the modules which are used to confirm making the round and determines the time interval
between successive rounds. If such a user is granted access to the partition, he/she will
have the same possibilities as the N
ORMAL
type user.
Scheduled
– the user has access to the system as per the time schedule for a specified
period of time. It is necessary to select the schedule (the schedule is programmed by the
installer) and define the user validity period.
5.8.2 Adding new user
1. Enter the code and confirm with the key.
2. Press in turn the 2 and 1 keys. The list of functions to define the user parameters will be
displayed.
If the service code has been entered, before the list of functions is displayed, it is
necessary to specify the object in which the new user is to be created (the service
code enables access to all objects).
3. Using the appropriate functions, define the user's parameters.
At least one identifier, i.e. code, proximity card, DALLAS iButton or keyfob, must be
assigned to the user.
The new user may not be granted a higher authority level than the person who is
adding that user to the system.
4. Press the key.
5. When a prompt appears, asking you if the changes are to be saved, press the 1 key.
6. A message will inform you that a new user has been created. Press the key to return to
the U