38 User
Manual
SATEL
6.2.2 [Code]
Depending on the user type and authority level, keypad settings and the alarm system status,
entering the code and confirming with the key will execute one or a few of the following
functions:
starting the partition arming procedure / arming,
disarming the partition,
clearing alarm,
changing over the status of 25. BI
SWITCH
type outputs,
turning on the 24. MONO
SWITCH
type outputs,
guard round confirmation,
enabling temporary partition blocking,
unblocking cash machine access.
6.2.3 Quick arming
The installer can permit arming without the user authorization.
1. Select the arming mode (press one of the keys: 0 – full arming; 1 – full
bypasses; 2 – arming without interior; 3 – arming without interior and without entry delay).
2. Press the key. The arming procedure will begin.
6.2.4 Triggering the alarm from keypad
The installer can permit triggering alarms from the keypad. To trigger an alarm, do the
following:
fire alarm
– press the
(INT-S) /
(INT-SK) /
(INT-SCR) key for approx. 3
seconds,
medical (auxiliary) alarm
– press the 0 key for approx. 3 seconds,
panic alarm
– press the
(INT-S) /
(INT-SK) /
(INT-SCR) key for approx. 3
seconds. The installer defines whether the triggered alarm will be loud (setting off the loud
alarm signaling) or silent (without loud signaling).
6.2.5 Silencing the alarm sound at the keypad
If the keypad is signaling alarm, pressing any digit key will silence the signaling for approx. 40
seconds.
6.2.6 Code changing
The installer can permit the change of own code by means of the partition keypad.
1. Press the 1 key for 3 seconds.
2. When the
and
LEDs start blinking alternately, enter the old code and confirm it
with the key.
3. When the and
LEDs start blinking alternately, enter the new code and confirm it
with the key.
7. Using the entry keypad
The INT-SCR multifunction keypad can work in the entry keypad mode (INT-ENT). The main
task of the zone keypad is activation of the delay for the 3. I
NTERIOR DELAYED
type zones. The
time period during which these zones will act as delayed ones is programmable for the