42 Programming
SATEL
61. T
ECHNICAL
–
GSM
LINK TROUBLE
– intended for control of the external GSM
communication module. Violation of the zone will cause a trouble condition.
62. T
ECHNICAL
–
OVERLOAD
– intended for control of an additional power supply unit used
together with the control unit. Violation of the zone will cause a trouble condition.
63. T
ROUBLE
– violation of the zone will cause a trouble condition.
64...79 B
YPASSING
–
GROUP
:
1–16
– violation of this type of zone can bypass a group
of zones (see: B
YPASSES
p. 45).
80. A
RMING
– violation of the zone will arm the partition to which the zone belongs.
Additionally, you can select a group of partitions which will also be armed (see: G
ROUPS OF
PARTITIONS
p. 46).
81. D
ISARMING
– violation of the zone will disarm the partition to which the zone belongs.
Additionally, you can select a group of partitions which will also be disarmed (see: G
ROUPS
OF PARTITIONS
p. 46).
82. A
RM
/D
ISARM
– the zone controls the arming status of the partition it belongs to.
The
control mode depends on the C
ONTROL BY PULSE
option. Disarming may
simultaneously clear the alarm and cancel the messaging.
83. C
LEARING ALARM
– violation of the zone will clear alarm in the selected group of partitions
(see: G
ROUPS OF PARTITIONS
p. 46) or the partition to which the zone belongs, and can also
cancel messaging.
84. G
UARD
– violation of the zone is recognized as recording the guard's round in the partition
to which the zone belongs.
85. E
NTRY
/E
XIT
–
CONDITIONAL
– similarly as the 0. E
NTRY
/E
XIT
type with an extra feature: the
zone becomes an instant one upon arming, if no partition exit is registered upon starting
the arming procedure.
86. E
NTRY
/E
XIT
–
FINAL
– similarly as the 0. E
NTRY
/E
XIT
, but the zone restore during exit delay
countdown will terminate the exit delay countdown and arm the system.
87.
E
XIT
–
FINAL
– similarly as the 6. E
XIT
, but the zone restore during exit delay countdown
will terminate the exit delay countdown and arm the system.
88. 24
H BURGLARY
– a permanently armed zone. Its violation will cause the burglary alarm.
89. F
INISHING EXIT DELAY
– zone violation will reduce the partition exit delay time. It is possible
to program a shorter exit delay time. If this value remains not programmed, the exit time
will be reduced to 4 seconds from the zone violation. There will be no effect if the zone is
violated and the just running exit delay is shorter than that programmed for the zone.
90. D
ISABLING VERIFICATION
– zone violation will disable verification of alarms in the partition.
All alarms will be unverified until next arming.
91. D
ETECTOR MASK
– the permanently armed zone, dedicated to anti-masking control.
Violation of the zone will be treated by the control panel as detector trouble (masking).
92. O
UTPUTS GROUP OFF
– the zone allows to deactivate a selected group of outputs.
93
.
O
UTPUTS GROUP
ON
– the zone allows to activate a selected group of outputs.
3.3.6 Zone options
Power up delay
– when the option is enabled, the zone will be bypassed for 120 sec. after
power-up (which prevents triggering alarms e.g. when starting the alarm control panel).
Priority
– when this option is enabled, arming will be impossible, if the zone is violated (e.g.
windows have been left open, etc.).
Violation control
– option for 82. A
RM
/D
ISARM
zone type. If it is enabled, violation of the zone
will arm/disarm the partition (depending on the current status of the partition). If the option
is disabled, zone violation will arm, and the zone restore will disarm the partition.