SATEL INTEGRA
Plus
45
Blocks verification
– option for 0-2 and 85-86 zone types. If it is enabled, violation of the
zone will block verification of alarms in the partition. All alarms will be unverified until the
partition is armed again.
Check arm possibility
– option for the arming zones (80 and 82 zone types). The zone will
not arm, if a zone with enabled P
RIORITY
option is violated in the partition, or other
circumstance have occurred which prevent arming (depending on the selected options,
tamper, trouble, etc.).
Restore disarms
– option for the 89. F
INISHING EXIT DELAY
zone type. If it is enabled, the
zone restore will disarm the partition. This option overrides the option R
ESTORE DISABLES
VERIFICATION
.
Restore disables verification
– option for the 89. F
INISHING EXIT DELAY
zone type. If it is
enabled, the zone restore will disable verification of alarms in the partition. All alarms will
be unverified until the partition is armed again.
Disabled in arm state
– option for the 91. D
ETECTOR MASK
zone type. If the option is enabled
and the zone is violated when armed, the information on detector trouble (masking) will not
be stored into the event log (the event code will not be sent to the monitoring station).
3.3.7 Counters
The control panel makes it possible to program 16 different counters which determine the
operating mode of the counter zones (zone types 16-31). The counter parameters can be
programmed:
using the keypad, in the service mode, by means of the C
OUNTERS
function (
Z
ONES
C
OUNTERS
).
using the D
LOAD
X program, in the ”Zones” window, "Counters" tab.
The following should be programmed for each counter:
Maximum value
– number of violations which, if exceeded, will trigger an alarm.
Counting time
– the time in which violations are counted.
Counter type:
normal
– all violations of counter group zones are counted;
omit recurs
– skips violations of the same zone (the alarm will be triggered, if the number
of violations of different zones exceeds the maximum value).
If the counter skips repeats, the programmed M
AXIMUM COUNTER VALUE
must be lower
than the number of zones in counter group.
3.3.8 Bypasses
You can define a group of zones for each of the zone types from 64 to 79:
using the keypad, in the service mode, by means of the B
YPASSES
function (
Z
ONES
B
YPASSES
).
using the D
LOAD
X program, in the ”Zones” window, "Bypasses" tab.
Having assigned the zones to a group, define what reaction should be to violation of the
bypassing zone:
Bypass only
– the zones belonging to the group will be bypassed for B
YPASS TIME
(see:
p. 38).
Bypass on/off –
the zones belonging to the group will remain bypassed as long as the
bypassing zone is violated (they can be bypassed by the user).
In the LCD keypad, use the B
YPASS ON
/
OFF
option to make your selection. Option
disabled – see: B
YPASS ONLY
. Option enabled – see: B
YPASS ON
/
OFF
.