the "Configuration" window, "Modem" tab). A suitable message will inform about the
connection being established.
Connection initiated by the control panel – external modem
1. Click on the
button in the D
LOAD
X program.
2. A drop-down menu will be displayed. Select the "Modem - INTEGRA with ext. modem" in
it. A window will open in which modem initialization information will be displayed.
3. In the LCD keypad connected to the control panel, start the S
TART
DWNL-MOD function
([
code
]
D
OWNLOADING
S
TART
DWNL-MOD). The function is available to the installer,
administrator and user having the D
OWNLOADING STARTING
right.
4. The control panel will call the programmed computer telephone number.
5. The D
LOAD
X program will answer the connection automatically or the program user must
accept establishing the communication (which depends on the settings programmed in
the "Configuration" window, "Modem" tab). A suitable message will inform about the
connection being established.
2.2.7 Starting remote programming via Ethernet network
Programming through the Ethernet network is possible, if the ETHM-1 module is connected
to the control panel (the RS-232 ports of control panel and module must be connected).
The connection can be established in two ways:
1. Initiating connection from the D
LOAD
X program. This method enables establishing a
connection with the control panel from any location.
2. Initiating connection by the control panel. The control panel can only be remotely
programmed from a specific location. This method is applicable when the system user
does not want the remote programming to take place without the user's knowledge.
Configuring the alarm control panel and ETHM-1 module
In the control panel you must:
disable the local programming function (see section F
INISHING LOCAL PROGRAMMING
p. 26);
enable the E
XTERNAL MODEM
option;
enable the M
ODEM
ISDN/GSM/ETHM
option;
enable the A
NSWERING
-
ETHM/GSM
option.
In the ETHM-1 module you must:
program the number of TCP port which will be used for communication;
program the key with which the data sent through the Ethernet will be encrypted;
enable the D
LOAD
X
->
ETHM-1
CONNECTION
option if the connection is to be initiated by the
D
LOAD
X program;
program the network address of the computer with D
LOAD
X program (or the server whose
port has been redirected to the computer), if the connection is to be initiated by the control
panel.
The above-mentioned options and parameters can be programmed:
using the keypad, in the service mode (O
PTIONS
submenu and ETHM-1 module settings
[
H
ARDWARE
E
XPANDERS
S
ETTINGS
]);
using the D
LOAD
X program during local programming ("Options" window and ETHM-1
module settings in the "Structure" window, "Hardware" tab).