SATEL INTEGRA
Plus
63
5.8 Default user's authority level
You can define which user rights will be automatically assigned to a new user. The list of
permissions can be modified during user creating or editing.
6. Programming the keypads
You can program the keypads:
using the keypad, in the service mode, by means of the functions available in the LCD
K
EYPADS
submenu (
S
TRUCTURE
H
ARDWARE
LCD K
EYPADS
) – having selected the
S
ETTINGS
or N
AMES
function, choose the keypad;
using the D
LOAD
X program, in the "Structure" window, "Hardware" tab, after clicking on the
keypad name.
6.1 Keypad parameters and options
Shown in the square brackets are the names, as used in the keypads.
Name
– individual name of the LCD keypad (up to 16 characters).
Partitions managed by keypad
[Partitions] – partitions which can be armed/disarmed or
alarm in which may be cancelled from the keypad. These functions are available to the
users having appropriate rights and access to these partitions.
Using the service code you can operate all partitions, irrespective of which partitions
are operated by the keypad.
Show alarms of partitions
[Alarms] – the partitions, the alarm from which will be indicated
on the keypad by
LED, text message or a sound.
Show fire alarms of partitions
[Fire alarms] – the partitions, the fire alarm from which will be
indicated on the keypad by
LED, text message or a sound.
CHIME signal
[Chime zones] – list of the zones whose violation will generate a chime signal
in the keypad.
In the case of the INTEGRA 256 Plus control panel, violation of zone numbers 129 to
256 will be indicated by the keypads with firmware version:
INT-KLCD / INT-KLCDR – 1.12 (or newer);
INT-KLCDK / INT-KLCDL / INT-KLCDS – 6.12 (or newer);
INT-KSG – 2.00 (or newer).
Zone disabling CHIME
[Chime bps. zone] – zone, which, if violated, will disable the CHIME
feature for specified time.
The zone 256 cannot disable the CHIME feature.
Bypass time
[Chime bps. time] – time during which the CHIME signal will be disabled after
violation of the zone which disables the signaling (time is counted from the zone restore). If
the value 0 is programmed, the signaling will not be disabled.
Quick Arm partitions
[Quick Arm] – partitions which will be armed in case of the quick
arming (see: U
SER MANUAL
).
Show entry delay of partitions
[Entry time p.] – the partitions for which counting the entry
delay will be indicated by text appearing on the LCD display.
Show exit delay of partitions
[Exit time p.] – the partitions for which counting the exit delay
will be indicated by text appearing on the LCD display.
Date/Time format
– the format in which the date and time are to be displayed on the keypad.
LCD backlight
– selection of the display backlighting type.