SATEL INT-TSG
19
– zone status by means of messages (select individual zones whose status will be
displayed, and define the content and color of messages for normal state and for
violation, because only these two states are presented in the form of message),
– output status by means of messages (select individual outputs whose status will be
displayed, and define the content and color of messages for active and inactive output).
There are three font sizes available for use on the status screen. You can also define color of
the font to be used. Using the “drag and drop” method, you can easily select the place where
the given information will be presented on the display.
Slide show
The keypad can display a slide show (as the status screen background and after 10 minutes
of the keypad inactivity). The photos to be displayed should be stored on a microSD memory.
Their size should not exceed 480 x 272 pixels. Only images in BMP format are supported.
The C
HANGE PICTURE EVERY
parameter defines how fast the images will be changed during
the slide show. If the time equal to 0 is programmed, no slide show will be displayed. If this is
the case, the first picture stored on the microSD card will be displayed as the status screen
wallpaper.
7.1.6 End-of-line resistance
The resistance data are stored in the keypad. Before you start programming the
resistor values, click on the “Read” button in the “EOL resistance value” tab to read the
data from the keypad. Having programmed the resistor values, click on the “Write”
button in the “EOL resistance value” tab to write the data to the keypad. The EOL
resistors related data are not read / written when you click on the
button in the
main menu of D
LOAD
X program.
2EOL/NC
Z
COM
R1
R2
A
T
3EOL/NC
Z
COM
R1
R2
A
T
R3
M
Fig. 9. Numbering of EOL resistors (same for the NO detector).
T – tamper. A – alarm. M – masking.
The value of EOL resistors is programmable. Depending on the control panel to which the
keypad is connected:
INTEGRA
: parameters of the EOL resistors should be defined for zones in a single keypad.
Value of the resistors R1 and R2 is to be programmed (numbering of the resistors is
shown in Fig 9). You can enter values from 500
to 15 k
. The total resistance (R1+R2)
may not exceed 15 k
. For the R2 resistor, you can program value 0. In such a case, the
value of resistors used in the Double EOL configuration must be equal to half the value