18 INT-TSG
SATEL
Fig. 8. D
LOAD
X program: “Status screen” tab (keypad connected to INTEGRA / INTEGRA
Plus control panel).
The status screen is displayed automatically after the keypad is idle for 60 seconds. This rule
does not apply if the terminal is running. In such a case, the status screen may be displayed
later or even will not be displayed at all (e.g. when the service menu is open). The following
information can be displayed on the status screen:
– any text defined by the installer,
– partition status by means of symbols (select individual partitions whose status will be
displayed),
– zone status by means of symbols (select individual zones whose status will be
displayed),
– output status by means of symbols (select individual outputs whose status will be
displayed),
– temperature (indicate the control panel zone to which the temperature detector is
assigned, and define whether the temperature is to be displayed in Celsius or
Fahrenheit degrees),
– date and time (particular elements, such as day, month, year, hour, minutes and
seconds are to be configured individually),
– keypad name,