background image

The  GPRS-T1  converter is a  device  dedicated for use in  intruder  alarm systems  for the 
purpose of reporting and messaging via the GSM networks.  The event codes received in 
the telephone format  can be  converted to the form transmittable with the use of GPRS 
technology or to the SMS message format. Using the GPRS technology makes it possible 
to send the codes to the STAM-2 monitoring station or SMET-256 converter. The codes in 
SMS  format can be sent to any  monitoring station which  supports  the SMS reporting 
feature. Apart from the event code conversion function, the device offers the capability of 
using SMS messages or CLIP service for notification about occurrence of selected events. 

In order to execute some functions, the converter  makes use of  the features offered by 
the CLIP  service,  which enables identification of the calling party and presentation of its 
telephone number. Thus, test transmissions can be generated and sent without incurring any 
costs whatsoever. 

 

 

Fig. 1. Basic applications of the converter. 

 

1.  C

ONVERTER FEATURES

 

  Simulation of telephone monitoring station. 

  Receiving reporting codes sent in DTMF telephone format (Ademco Express or Contact ID) 

or in SIA format. 

  Conversion and retransmission of event codes to two monitoring stations. 

  Acknowledgment of event receipt: 

–  after sending SMS message (code conversion to SMS format); 

–  after  acknowledgment of event receipt by the  monitoring station (code conversion to 

GPRS transmittable form); 

–  immediately on receiving the event (SMS messaging and CLIP service). 

  Capability to automatically replace the GPRS transmission with SMS message, if there are 

problems with GPRS transmission. 

Содержание GPRS-T1

Страница 1: ...Monitoring Converter GPRS T1 Program version 2 01 gprs t1_en 11 11 SATEL sp z o o ul Schuberta 79 80 172 Gdańsk POLAND tel 48 58 320 94 00 info satel pl www satel eu ...

Страница 2: ... that enables GPRS SMS CLIP reporting for control panels with analog telephone line monitoring dialer intended for intruder alarm systems The product is in conformity with the following EU Directives RTTE 1999 5 EC EMC 2004 108 EC LVD 2006 95 EC The product meets the requirements of harmonized standards EN 50130 4 1995 A1 1998 A2 2003 EN 61000 6 1 2007 EN55022 2006 A1 2007 EN 61000 6 3 2007 EN 609...

Страница 3: ...ctions the converter makes use of the features offered by the CLIP service which enables identification of the calling party and presentation of its telephone number Thus test transmissions can be generated and sent without incurring any costs whatsoever Fig 1 Basic applications of the converter 1 CONVERTER FEATURES Simulation of telephone monitoring station Receiving reporting codes sent in DTMF ...

Страница 4: ...one and an indicator of troubles connected with logging into the GSM network Output for signaling problems with logging into the GSM network Converter configuration locally through the RS 232 TTL port remotely through the GSM network GPRS technology Automatic module restart Power supply with 12 V DC 15 2 DESCRIPTION OF ELECTRONICS BOARD Fig 2 View of converter electronics board Explanations for Fi...

Страница 5: ...PIN code F LEDs are blinking logging into GSM network has failed invalid PIN code G LEDs are blinking logging into GSM network has failed SIM card has been blocked after three attempts to use an invalid PIN code PUK code must be used to unblock the SIM card Description of terminals 12V power supply input 12 V DC 15 COM common ground TIP RING terminals for connecting the control panel telephone com...

Страница 6: ...2V and COM terminals 4 Connect the computer to the converter RS 232 TTL port see section Local programming through RS 232 TTL port 5 Turn on the converter power supply 6 Using the GPRS SOFT program define PIN code for the SIM card if the card requires entering the PIN code to be installed in the converter 7 Turn off the converter power supply 8 Insert the SIM card into the socket see Fig 4 9 Turn ...

Страница 7: ... programmed locally 4 1 LOCAL PROGRAMMING THROUGH RS 232 TTL PORT The serial COM port of the computer must be connected with the RS 232 TTL port on the converter electronics board The cables for making this connection are available as a set designated DB9FC RJ KPL Indicate in the GPRS SOFT program the computer COM port to be used for communication with the converter To do so click on the Configura...

Страница 8: ...sh communication between the converter and the computer do the following 1 Start the GPRS SOFT program 2 Click on the Configuration button see Fig 6 and explanations for the figure and in the window that will open enter the number of TCP port selected for communication with the converter The number will have to be included in the body of SMS message which will be sent to the converter GSM telephon...

Страница 9: ...tton color indicates the current communication status green computer COM port enabled server active gray computer COM port disabled server inactive 9 button for selecting the mode of communication with the converter local programming through the RS 232 port or remote programming with the use of GPRS technology and TCP IP protocol 10 information on the mode of communicating with the converter COMn ...

Страница 10: ...ort are indicated in the SMS message Fig 7 GSM telephone Monitoring stations tab GSM telephone PIN SIM card PIN code if the card requires entering the PIN code Note Entering invalid PIN code may result in blocking the SIM card SMS center number telephone number of the Short Message Service Center which delivers SMS messages Entering the number is necessary if the converter is to send SMS messages ...

Страница 11: ... to the module If 0 is entered the function will be disabled Monitoring station 1 Monitoring station 2 Notes Using GPRS technology event codes can be sent to the STAM 2 monitoring station or to the SMET 256 converter Communication with the subscriber sending event codes with the use of GPRS technology should be tested by the monitoring station as rarely as possible if a value lower than 1 minute i...

Страница 12: ...t identifier Do not enter value 0000 the converter will not be sending test transmissions to the monitoring station Using digit 0 in the identifier is not recommended Obtain identifier automatically select this box if the control panel identifier is to be used by the converter for converter s own test transmissions Enabling this option is not recommended when several identifiers are used by the co...

Страница 13: ...he field is available if you select the Custom settings option SMS format The format of SMS messages for SMS reporting must be defined according to the monitoring station requirements The default SMS messages format programmed in the converter corresponds to the factory default settings of the STAM 2 monitoring station program version 1 2 0 or later The symbols used for programming the SMS format ...

Страница 14: ...est transmission can be sent to the monitoring stations The method of sending the event code SMS GPRS depends on the rules defined for each monitoring station in the GSM telephone Monitoring stations tab It is necessary to define the event code to be sent Event codes for converter test transmission The table makes it possible to define the codes which will be sent to the monitoring stations for th...

Страница 15: ...o define the form in which the test transmissions will be sent to the telephone numbers programmed in the GSM telephone Monitoring stations tab Click twice on the chosen field to select deselect it the field is selected if the x symbol is displayed in it SMS select this field if the converter test transmission is to be sent to the selected telephone number in the form of SMS message CLIP select th...

Страница 16: ...hone Monitoring stations tab on the Telephone numbers for messaging and test transmissions list Note If the Reaction to CLIP only when number is on list of telephones for messaging option is not enabled the test transmissions and SMS messages with information on device status for the numbers in the list they will be sent by the converter immediately for the numbers not in the list they can be sent...

Страница 17: ...es is also available in the Event field T1 T4 define to which telephone numbers see numbers programmed in the GSM telephone Monitoring stations tab in the Telephone numbers for messaging and test transmissions list and how the messaging about receiving the event code is to be executed You can choose from the following options blank field no messaging s SMS messaging c CLIP service notification sc ...

Страница 18: ...rs related to the simulation of monitoring station enter the telephone number defined in the control panel for the monitoring station which is to be simulated by the converter define whether the converter is to simulate a telephone line failure if the GSM telephone fails to log into the GSM network Cut off the telephone line voltage if GSM failure option for events in the Ademco Express or Contact...

Страница 19: ...orted by the converter to which telephone numbers and in what way Test transmissions CLIP SMS messaging tab enter the identifier that must be received with the event code so that the converter can effect the CLIP SMS messaging Ident field define the format in which the event code must be received so that the converter can effect the CLIP SMS messaging Format field enter the event code the receipt ...

Страница 20: ...Kiss off time 600 ms SIA kiss off Custom settings Kiss off time 100 ms Kiss off delay 100 ms SMS format Event Test transmissions CLIP SMS messaging tab CLIP Reaction to CLIP only when number is on list of tel for messaging the option is enabled CLIP SMS messaging Format 4 2 6 SPECIFICATIONS Supply voltage 12 V DC 15 Current consumption standby 50 mA Current consumption max 220 mA Current carrying ...

Отзывы: