53
Address Point
ID
Description
Options/Range/Format
2
Units
2
Type R/W
Notes
+98,99
Timestamp
sec UINT32
R
+100,101
+102,103
0x3419
Max. I2 K-Factor
Timestamp
10-9999
×
0.1
sec
UINT32
UINT32
R
R
3
+104,105
+106,107
0x341A
Max. I3 K-Factor
Timestamp
10-9999
×
0.1
sec
UINT32
UINT32
R
R
3
+108,109
+110,111
0x341B
Max. I1 Current TDD
Timestamp
0-1000
×
0.1%
sec
UINT32
UINT32
R
R
3
+112,113
+114,115
0x341C
Max. I2 Current TDD
Timestamp
0-1000
×
0.1%
sec
UINT32
UINT32
R
R
3
+116,117
+118,119
0x341D
Max. I3 Current TDD
Timestamp
0-1000
×
0.1%
sec
UINT32
UINT32
R
R
3
37120-37135
Maximum Total Values
+0,1
+2,3
0x3500
Max. Total kW
Timestamp
-Pmax-Pmax U3
sec
INT32
UINT32
R
R
+4,5
+6,7
0x3501
Max. Total kvar
Timestamp
-Pmax-Pmax U3
sec
INT32
UINT32
R
R
+8,9
+10,11
0x3502
Max. Total kVA
Timestamp
0-Pmax U3
sec
UINT32
UINT32
R
R
+12,13
+14,15
0x3503
Max. Total PF
Timestamp
-1000-1000
×
0.001
sec
INT32
UINT32
R
R
37376-37387
Maximum Auxiliary Values
+0,1
+2,3
0x3600 Not
used
UINT32
UINT32
R
R
+4,5
+6,7
0x3601
Max. In Current
Timestamp
0-Imax U2
sec
UINT32
UINT32
R
R
+8,9
+10,11
0x3602
Max. Frequency
Timestamp
0-Fmax
×
0.01Hz
sec
UINT32
UINT32
R
R
37504-37535
Billing Summary Maximum Demands
+0,1
+2,3
0x4780
Summary register #1 Maximum Demand
Timestamp
0-Pmax U3
UINT32
R
+4,5
+6,7
0x4781
Summary register #2 Maximum Demand
Timestamp
0-Pmax U3
UINT32
R
…
+28,29
+30,31
0x4783
Summary register #8 Maximum Demand
Timestamp
0-Pmax U3
UINT32
R
37632-37695
Maximum Demands
+0,1
+2,3
0x3700
V1/V12 Maximum volt demand
Timestamp
0-Vmax U1
sec
UINT32
UINT32
R
R
1
+4,5
+6,7
0x3701
V2/V23 Maximum volt demand
Timestamp
0-Vmax U1
sec
UINT32
UINT32
R
R
1
+8,9
+10,11
0x3702
V3/V31 Maximum volt demand
Timestamp
0-Vmax U1
sec
UINT32
UINT32
R
R
1
+12,13
+14,15
0x3703
I1 Maximum ampere demand
Timestamp
0-Imax U2
sec
UINT32
UINT32
R
R