Dear    buyer    and    user    of    boiler    of    SAS    MULTI    type,    this    technical    start-up  
documentation   contains   all necessary  information required for  energy-saving, safe 
and longstanding exploitation of your boiler.  
We    kindly    ask    you    to    get    familiar    with    documentation    content    prior    to  
assembling  and  starting  the exploitation of a boiler. Hereby documentation shall 
be kept for future use and for warranty

.  

 

 

 

 

SAS MULTI  type boilers  with  fuel  bunker  and  screw feeder  are  designated  for  
water  installations  of  the  central

 

heating systems, open type with  gravitational  or 

forced    water  circulation,  protected  according  to  presently  being  in    force,    both  
domestic  or  the  union  detailed  regulations  (e.g.  PN-91/B-02413  –  Boilers  of    
SAS MULTI  type installed in accordance to hereby documentation recommendations 
are    not  subject  to  the  commissioning  led  by  the    Branch  Office  of    Technical 
Inspection).   
Boilers  are  specifically  recommended  for    the  flats  heating    in  single-family  homes, 
pavilions,  etc.,  where calculated  feeding water  temperature does not exceed 85°C ,  
and  working  pressure    does    not    exceed    1,5    bar.        Required    gases    draught  
pressure  after  a  boiler  is  0,30  -  0,45  mbar (depending on boiler’s power). These 
boilers  may  also  work  in  hot  water  installations  utilizing  a  heat  exchanger.    Boiler’s 
selection  for    building    heating  should    be    based  on  heat  balance,    according  to  
regulations  in force,  both domestic and the union (e.g. PN-B-02025:2001). 

 

 

 

 
 
 

Heating  boiler  of    SAS  MULTI  type,  is  low  temperature  automated  boiler  for  
heating    installations,    with  water  body,  made  of  plates  and    steel  pipes  of  welded 
construction. 

 

Boiler  SAS GRO-ECO,  is  a  construction designed for high  effective, a back coal 
of pea coal grade fuel, combustion. Its granulation is 5 – 25 mm (energetic pea 
coal, washed, 31.2 type)
.  Basic  components of a boiler are illustrated on the 
drawing  (p.  15). 
 
The water jacket it is a cuboids shape structure with double walls, separated by water 
partitions.

 

Combustion chamber construction ensures to operate in the continuous two modes: 

 

In  automatic  combustion  boiler  functions  on  operation  an  automatic  fuel 
delivery system ( retort ), temperature controller, blowing fan;  

2.  

USE OF BOILER

 

3.  

BOILER CONSTRUCTION DESCRIPTION

 

1.  

INTRODUCTION

 

Содержание MULTI Series

Страница 1: ...M E T A L O W O K O T L A R S K I 28 100 Busko Zdr j Owczary ul Przemys owa 3 Phone 48 41 378 46 19 Fax 48 41 370 83 10 TECHNICAL START UP DOCUMENTATION of water boilers for heating installations SAS...

Страница 2: ...tallation 15 6 Operation and exploitation guidelines 16 6 1 Filling with water 16 6 2 Firing up and functioning of a boiler 16 6 2 1 Firing up and functioning of a boiler in automatic mode 17 6 2 2 Fi...

Страница 3: ...3...

Страница 4: ...ater temperature does not exceed 85 C and working pressure does not exceed 1 5 bar Required gases draught pressure after a boiler is 0 30 0 45 mbar depending on boiler s power These boilers may also w...

Страница 5: ...in the temperature set on the controller The controller constantly measures the temperature of water boiler Depending on the results it controls fuel feeder and ventilator At the same time the control...

Страница 6: ...arge cleaning door pos 6 furnace door pos 11 and ash box door pos 13 are placed on the boiler s front For periodic cleaning operations and also for firing up a boiler the retort may be accessed throug...

Страница 7: ...1200 1280 A1 mm 290 290 305 305 330 330 B mm 1110 1235 1235 1300 1300 1300 B1 mm 450 535 535 605 605 605 H mm 1430 1430 1490 1490 1590 1590 H1 mm 1300 1300 1375 1375 1475 1475 H2 mm 980 980 1050 1050...

Страница 8: ...door 14 air intake dosage flap 15 air draft regulator 16 connecting strip 17 hot water connector pipe 18 upper washout hole cover 19 smoke conduit clearing hole 20 smoke throttle 21 smoke conduit 22...

Страница 9: ...tent to 10 Ash melting temperature 1150 C Low coal swelling coal should not tend to stick when burner Volatile particles content 30 40 It is recommended to use coal which is prone to agglomeration cok...

Страница 10: ...allation shall be installed must conform the requirements of detailed regulations being in force at the country of destination e g PN 87 B 02411 In particular the following requirements shall be fulfi...

Страница 11: ...k draught may also cause or help in carbon black forming which is then settling down on the boiler s convection channels If the draught is too strong it will cause excessive air to draw into the retor...

Страница 12: ...system provided with three or four pass valve The main advantage of such connection is boiler protection function against low temperature corrosion preventing it from premature wear If not satisfacto...

Страница 13: ...d down 6 2 FIRING UP AND OPERATE A BOILER Before fuel fire up it is mandatory to check installation filling with water Water can t be frozen It must be checked also if there is no water leakage on boi...

Страница 14: ...as varying fuel quality may cause the boiler to burn out If the fire is out during up phase the furnace should be cleaned and boiler s channels ventilated and the whole starting procedure must be rep...

Страница 15: ...ve At the same time the controller operates the heating system circulation pump if such is provided Heat requirement in the heat installation is varying due to changing outdoor conditions such as the...

Страница 16: ...t those adverse phenomena should go away During normal exploitation of boiler in the traditional combustion mode burning process is based on periodic refueling Single load of basic fuel is sufficient...

Страница 17: ...of burned fuel and apply cleaning and conservation of the entire boiler Pay special attention to lubricate inner partitions of combustion chamber and all movable elements with oil For the period of br...

Страница 18: ...ection channels walls disrupts proper heat transfer from the exchanger lowering this way an efficiency of device and increases fuel consumption 6 6 OPERATE AND MAINTENACE OF A FEEDER AND RETORT Feeder...

Страница 19: ...nstallation improper functioning of controller or fan adjust controller s settings up to weather conditions or quality of fuel mainly feeder operation time and fuel delivery pauses should be changed t...

Страница 20: ...oal reduce the set of fuel supply by 5 10 or increase blow in power Wait 20 30 minutes until such changes come to effect what should be deflected in change of fire state In order to ensure the failure...

Страница 21: ...arried out by authorized team Before connecting a boiler to a heating installation make check if all boiler s components are in good working condition and that the boiler is fully equipped NOTE Boiler...

Страница 22: ...on alterations made by user or other third parties will cause the warranty to be invalid 8 Application of reclamation should be addressed at manufacturer 9 Boiler replacement realized by manufacturer...

Страница 23: ...umentation however basic described properties of the product shall be maintained Any remarks and questions on boiler s SAS type exploitation shall be addressed ZAK AD METALOWO KOTLARSKI Owczary ul Prz...

Страница 24: ...24 SERVICE REPAIRS...

Страница 25: ...25 SERVICE REPAIRS...

Страница 26: ...perature boiler of SAS MULTI type installed and operated in pursuance of Technical Start Up Documentation Boiler no Heating capacity Heated surface Year of manufacture Manufacturer signature and stamp...

Отзывы: