Commissioning
PR 5610 Installation Manual
82 Sartorius
Enter minimum weight for print-out with numeric keys from 0 to
9999999 d; confirm with
.
Enter the increase in weight per x count(s) with numeric keys,
numeric range depends on FSD. Change the weight dimension
from [kg] to [t], [lb] or [g] with
; confirm with
.
Enter the number of counts with numeric keys necessary to get
the defined weight increase, confirm with
.
Enter time interval for weight data transfer from the external
weighing point with numeric keys; confirm with
.
Enter SPM address, to which the weight data have to be routed;
confirm with
.
Enter board number of a connected scale with numeric keys, if it
has to be checked ; confirm with
. In the case of non-
conformity error 15 is displayed.
Automatic return to the weighing point selection menu.
4.6.4 Weighing point function xBPI-scale
With the xBPI-scale the tare function has to be defined according to the application. Additionally the update
time has to be defined. Furthermore a serial number can be entered.
With [Config] the configuration of the xBPI-scale can be
accessed. For further information please refer to 0 xBPI-scale.
Select W
&
M mode [none], [OIML], [NTEP] with
or
; confirm
with
.
Select tare mode [Remote] or [Local] with
or
; confirm
with
. [Remote] has to be selected for an ISI-terminal. The tare
function is not carried out in the PR 5610. [Local] has to be
selected for a xBPI-platform. The tare function is carried out in
the PR 5610.
Enter the overload range > FSD with numeric keys from 0 to
9999999 d; confirm with
.
Enter minimum weight for print-out with numeric keys from 0 to
9999999 d; confirm with
.
Enter time interval for weight data transfer from the external
weighing point with numeric keys; confirm with
.
Automatic return to the weighing point selection menu.