d
Disable the relay selection mode.
01
58th minute (1)
- The hourly correction for 55 seconds every hour from XX:58:05 to XX:59:00. The daily correction (5 a.m. &
5 p.m.) is ten correction cycles sent to the relay (each for 95 seconds) beginning at 5:05:00, 5:07:00, 5:09:00, 5:11:00, 5:13:00,
5:15:00, 5:17:00, 5:19:00, 5:21:00, and 5:23:00.
02
58th minute (2)
- The hourly correction for 60 seconds every hour from XX:58:00 to XX:59:00. The daily correction (5 a.m. & 5
p.m.) is twelve correction cycles sent to the relay (each for 65 seconds on and 25 seconds off) beginning at 5:05:00 to 5:22:35.
03
58th minute (3)
- The hourly correction for 60 seconds every hour from XX:58:00 to XX:59:00. The daily correction (5 a.m. & 5
p.m.) is twelve correction cycles sent to the relay (each for one minute on and two minutes off) beginning at 5:06:00.
04
58th minute (4)
- The hourly correction for 55 seconds every hour from XX:58:05 to XX:59:00. The daily correction (5 a.m. &
5 p.m.) is 12 correction cycles for 55 seconds. The timings will be 05:03:05, 05:07:05, 05:11:05, 05:15:05, 05:19:05, 05:23:05,
05:27:05, 05:31:05, 05:35:05, 05:39:05, 05:43:05 and 05:47:05.
05
59th minute
- The hourly correction for 8 seconds every hour from XX:57:54 to XX:58:02. The daily correction (5 a.m. & 5 p.m.)
is a 14 second pulse from 5:57:54 to 5:58:08.
06
National Time & Rauland (1)
- The hourly correction is for 25 seconds every hour from XX:00:00 to XX:00:25. The daily
correction is a 24 minute pulse from 6:00:25 to 6:24:25 AM and PM.
07
National Time & Rauland (2)
- The hourly correction is for 25 seconds every hour from XX:00:00 to XX:00:25. The daily
correction (6 a.m. & 6 p.m.) is 25 seconds on, 35 seconds off every minute for 24 minutes.
08
Rauland Digital
- Every .5 second advances the time 1 minute from 12:00:00 a.m.
09
Once a Day Pulse
- If selected, this option will allow the user to set the hours, minutes, and seconds for relay closure.
Table 3 - Relay Selection Mode
Option 20 - Set the Programmable Relays:
This option will allow the user to set the programmable relays.
The programmable relays allow a user to choose the type of
time correction the clocks will conduct when the clocks reach
a certain time. Press the bottom button to scroll between “
d
”
and “
01-09
.”
If Option
20
is set to “
d
” (disable) or “
01-08
,” when the top
button is pressed, the user will be taken to Option
30
.
If option
“
09
” is selected, the user will be taken to options “
21-24
” to
configure the Once a Day Pulse settings.
See Table 3 below for explanation of relay selection mode for
time correction.
Note:
Refer to page 12 for wiring information.
20 08
Option 15 - Enable Jumpers:
This option will allow the user to enable or disable the jumpers
inside the clock. There are 3 jumpers located inside the clock
that are associated with this option:
•
Jumper 1 - 12/24 Hour Format
•
Jumper 2 - Brightness Level
•
Jumper 3 - Alternating Date/Time
Press the bottom button to scroll between “
E-d
.”
Selecting (
E
) will allow the user to set the jumpers and selecting
(
d
) will disable the jumpers. Once a user enables or disables the
jumpers, press the top button to continue on to Option
20
.
Note:
Enabling this option will override the previously
configured settings for options 4, 6 and 8.
15 d
OPTION
SETTING
Pr
og
ramm
in
g