INSTALLATION METHOD
1
Power supply unit removal
1
Press in the power supply unit removal lever (A) until it
clicks, then turn the power supply unit (C) in the direction
of the arrow and pull it away from the camera unit (B).
2
Gently push the safety wire (D) into its holding slot and
move it in the direction of the arrow until it can be
removed. This is done to help the installation go smoothly.
2
If the safty wire has been removed, take the safety wire
stowed in the power supply unit and attach it to the
camera unit.
Reversing the safety wire removal procedure, reliably reattach
the safety wire. (E)
3
Attach the camera unit to the power supply unit
Match the camera unit alignment notches (F) with the power
supply unit lever slot (F), then turn the camera unit in the
direction of the arrow.
A clicking sound will be heard when the power supply unit
removal lever drops into place, indicating that the camera unit
is properly set.
Note:
•
The camera unit is not properly set if a clicking sound is not
heard. Check that the unit is firmly set.
•
Do not continue to turn the camera unit after it has been
properly set. Doing so could damage the camera.
C
B
A
D
F
E
F
Consumable items:
The following parts are consumable items, so please replace
them after their worklife has expired. Moreover, component
performance cannot be guaranteed when parts are used to the
very end of their projected worklife. Durability will differ
according to environmental conditions and usage.
•
Lens: about 20,000 hours (1,200,000 operations)
•
Slip Ring: about 20,000 hours (1,200,000 rotations)
•
Motor: about 33,000 hours (12,000,000 revolutions)
•
Fan: 30,000 hours
– 4 –
English