2. SPECIFICATIONS
2-1. Unit Specifications
DATA SUBJECT TO CHANGE WITHOUT NOTICE.
Remarks: Rating conditions are:
Indoor air temperature 27°C D.B. / 19°C W.B.
Outdoor air temperature 35°C D.B. / 24°C W.B.
2
No. of indoor units.
1-unit
2-units
Power Source
220 / 230 / 240 V Single phase 50 Hz
Cooling
Capacity
kW
2.30
4.60
BTU/h
7,800
15,700
Air circulation (High)
m3/h
430
430
✕
2
Moisture removal (High)
Liters/h
0.8
0.8
✕
2
Voltage rating
V
220 / 230 / 240
Available voltage range
V
198 to 264
Running amperes
A
3.5 / 3.5 / 3.5
6.5 / 6.5 / 6.5
Power input
W
750 / 780 / 800
1,410 / 1,450 / 1,500
Power factor
%
97 / 97 / 95
99 / 97 / 96
C.O.P.
W/W
3.1 / 2.9 / 2.9
3.3 / 3.2 / 3.1
Compressor locked rotor amperes
A
17 / 18 / 19
34 / 36 / 38
Controls / Temperature control
Microprocessor / I.C. thermostat
Control unit
Wireless remote control unit
Timer
1-hour OFF / 12-hour ON or OFF
Fan speeds
Indoor / Outdoor
3 and Auto / 1 (Hi)
Airflow direction (Indoor)
Horizontal
Manual
Vertical
Auto
Air filter
Washable, Anti – Mold
Compressor
Rotary (Hermetic)
Refrigerant / Amount charged at shipment
g
R22 / 1,320 ( 660
✕
2)
Refrigerant control
Capillary tube
Operation sound
Indoor – Hi / Me / Lo
dB-A
39 / 37 / 33
Outdoor – Hi
dB-A
53
Refrigerant tubing connections
Flare type
Max. allowable tubing length at shipment
m
7.5
Refrigerant tube
Narrow tube
mm (in.)
6.35 (1/4)
diameter
Wide tube
mm (in.)
9.52 (3/8)
Refrigerant tube kit / Accessories
Optional / Hanging wall bracket
Indoor Unit
Outdoor Unit
Unit dimensions
Height
mm
250
630
Width
mm
790
810
Depth
mm
174
275
Package dimensions
Height
mm
242
704
Width
mm
850
953
Depth
mm
312
369
Weight
Net
kg
7.0
48.0
Shipping
kg
10.0
52.5
Shipping volume
m3
0.06
0.25
Dimensions & Weight
Features
Electrical Rating
Performance
Indoor Unit
SAP – K91GJA
Outdoor Unit
SAP – CM1621GA