43
12-2. Checking Continuity of Fuse on
PCB Ass'y
●
Remove the PCB Ass'y from the electrical component
box. Then pull out the fuse from the PCB Ass'y.
●
Check for continuity using a multimeter as shown in
Fig. 6.
12-3. Checking Motor Capacitor
Remove the lead wires from the capacitor terminals, and
then place a probe on the capacitor terminals as shown
in Fig. 7. Observe the deflection of the pointer, setting
the resistance measuring range of the multimeter to the
maximum value.
The capacitor is “good” if the pointer bounces to a great
extent and then gradually returns to its original position.
The range of deflection and deflection time differ accord-
ing to the capacity of the capacitor.
Compressor motor
capacitor
Fan motor
capacitor
Multimeter
Fuse
PCB Ass’y
Fig. 5
Fuse
Fig. 6
Fig. 7
Содержание SAP-CM1621GA
Страница 49: ......
Страница 50: ...SANYO Electric Co Ltd Osaka Japan SM700468 11 00 200 Printed in Japan ...