22
Indoor Unit
Outdoor Unit
Complete Unit
Fan Motor
Fan Motor
Compressor
Performance at
220V Single phase 60Hz
Rating Conditions
Running Amps.
A
0.30
0.52
7.68
8.5
Power Input
kW
0.062
0.114
1.664
1.84
Full Load Conditions Running Amps.
A
0.30
0.52
9.48
10.3
Power Input
kW
0.062
0.114
2.064
2.24
Rating Conditions
: Indoor Air Temperature 27°C D.B. / 19°C W.B.
Outdoor Air Temperature 35°C D.B.
Full Load Conditions : Indoor Air Temperature 32°C D.B. / 23°C W.B.
Outdoor Air Temperature 43°C D.B.
Indoor Unit
SAP – K91GA (
✕
2)
Outdoor Unit
SAP – CM1821JA
Indoor Unit
Outdoor Unit
Complete Unit
Fan Motor
Fan Motor
Compressor
Performance at
220V Single phase 60Hz
Rating Conditions
Running Amps.
A
0.15
0.52
3.93
4.6
Power Input
kW
0.031
0.114
0.815
0.96
Full Load Conditions Running Amps.
A
0.15
0.52
4.73
5.4
Power Input
kW
0.031
0.114
1.025
1.17
Rating Conditions
: Indoor Air Temperature 27°C D.B. / 19°C W.B.
Outdoor Air Temperature 35°C D.B.
Full Load Conditions : Indoor Air Temperature 32°C D.B. / 23°C W.B.
Outdoor Air Temperature 43°C D.B.
Indoor Unit
SAP – K91GJA (
✕
1)
Outdoor Unit
SAP – CM1821JA