Configure the following functions as needed
When set to “ON”, the manual panning/tilting speed may vary depending on the zoom factor selected, thus the
image scroll speed can be kept constant on the screen.
The greater the zoom factor, the slower the panning/tilting speed.
When set to “ON”, the most recent still image is provided all the while the camera's monitoring position is shifting
during sequence operation or preset position monitoring.
Once the monitoring position shift is complete, the still image will be switched to the moving image of a new
monitoring position.
When this function is enabled, the camera does not go into the area beyond the limit angle.
OFF, –20, –18, –16, –14, –12, –10, –8, –6, –4, –2, 0, 2, 4, 6, 8, 10, 12, 14, 16, 18, 20, 22
MANUAL: You can select any value from among above options for the limit angle, while tilting the camera to
view actual video images.
If a preset position was set beyond the limit angle you have just applied, the camera will stop tilting at
the point of the limit angle.
Use this feature if the bearing information is required to properly install the camera.
You can set zero degrees (North) to any direction.
1
Use the PZT controller to move the camera lens to the direction you want to set as the
reference bearing.
2
Select “ON” for [SET NORTH] and click
SET
.
3
Click
YES
on the confirmation dialog box.
If you select “OFF”, the panning position in the home position will be set to zero degrees.
When set to “ON”, images flip automatically when the camera tilts beyond 90 degrees (facing ground), thus
providing the normal view on the monitor.
DIGITAL
: Inverts the image electronically.
MECHANICAL
: Mechanically flips images.
OFF
: Stops tilting at an angle of 90 degrees (facing ground) as the end point.
Corrects automatically blurring images from a camera installed on a pillar, pole, wall or the like that is subject to
shake.
Select “ON” and specify a correction level for the sway of the camera in [LEVEL].
Working with Administrator Configuration Screens 42/77