E-14
Troubleshooting
Warning
¡
If the device is still operating abnormally after inspecting the following, stop using the device to prevent
accidents, unplug the power plug from the wall outlet and consult the place of purchase.
¡
Do not attempt to repair at home as this may be dangerous.
Does not operate
even when the air
is dirty.
The Electrolyzed
Water lamp is
flashing.
The sterile,
electrolytic mist
is not emitted.
There is an odor
of chlorine.
Water is leaking.
The add water
lamp is flashing.
The add water
lamp is on.
The clean
indicator is
continuously red.
Smoke and odors
are not removed.
Does not operate.
Condition
Inspect
Repair
¡
The automatic operation lamp (green) is flashing.
¡
Is the sensor sensitivity adjustment slide tab set
to “Mid” or “LOW”?
¡
Is the air inlet dirty and blocked?
¡
The Electrolyzed Water lamp flashes when cleaning the water to maintain its sterilizing
effect. The Water Cleaning function operates once every 8 hours for about 4 minutes.
¡
Has the electrolyzed water unit and tank been
properly installed?
¡
Is the electrolyzed water button turned “Off”?
¡
Is the water level in the electrolyzed water unit
high?
¡
This is from the electrolyzed water and is not a malfunction.
¡
Has the cap been placed correctly on the tank?
¡
It is time to replace the water.
¡
The electrolyzed water function has not been
used for an extended period of time.
¡
Is there water in the tank?
¡
Is the air very dirty?
¡
Are any insecticides or cosmetic devices that
may trigger the sensor being used?
¡
Are the filter and pre-filter installed?
¡
Is the power plug securely in the wall outlet?
¡
The sensor is configuring the air cleanliness
standard. This is not a malfunction.
¡
Set the sensor sensitivity adjustment slide tab to
“Mid” or “HIGH”.
¡
Clean the air inlet.
¡
Ensure that the installation is correct.
¡
Press the electrolyzed water button to turn “On”.
¡
Replace the water in the electrolyzed water unit.
¡
Retighten the cap correctly.
¡
Has the electrolyzed water unit been properly
installed?
¡
Install the electrolyzed water unit properly.
¡
Clean the electrolyzed water unit and replace
the water in the tank.
¡
Remove the tank and replace after waiting 20
seconds.
¡
Fill the tank with tap water.
¡
Remove the tank and replace after waiting 20
seconds.
¡
Ventilate the room.
¡
Is the sensor sensitivity adjustment slide tab set
to “HIGH”?
¡
Set the sensor sensitivity adjustment slide tab to
“Mid” or “LOW”.
¡
Install the filter and pre-filter.
¡
Is the air inlet dirty and blocked?
¡
Clean the air inlet.
¡
Is the filter or pre-filter dirty?
¡
Is the filter replacement lamp flashing?
¡
Replace the filter or clean the pre-filter.
¡
Has the plastic protector on the filter been
removed?
¡
Remove the plastic protector on the filter.
¡
Place the power plug securely in the wall outlet.
Power supply
: 120 V / 60 Hz
Current supply : 1.2 A
Net weight
: 15.9 lbs (7.2 kg)
Specifications
English
ABC-VW24A_GB_US.qxd 09.10.1 4:52 PM ページ14