1. Select
“/ Volume config / Cache volume”
.
2. Select a CV by clicking the checkbox in the row.
3. Click “
“. There will pop up a confirmation page.
4. Choose “OK”.
5. Done. The CV has been deleted.
Notice : Global cache volume cannot be deleted.
Step 12:
Done, all volumes have been deleted.
3.6 Enclosure management
“Enclosure management”
allows managing enclosure information including
“SES config”
,
“Hardware monitor”
,
“S.M.A.R.T.”
and
“UPS”
. For the enclosure management, there are many
sensors for different purposes, such as temperature sensors, voltage sensors, hard disks, fan sensors,
power sensors, and LED status. Due to the different hardware characteristics among these sensors,
they have different polling intervals. Below is the detail polling time intervals:
1. Temperature sensors: 1 minute.
2. Voltage sensors: 1 minute.
3. Hard disk sensors: 10 minutes.
4. Fan sensors: 10 seconds . When there are 3 errors consecutively, controller sends ERROR event
log.
5. Power sensors: 10 seconds, when there are 3 errors consecutively, controller sends ERROR event
log.
6. LED status: 10 seconds.
Figure 3.6.1
3.6.1 SES configuration
SES
represents
S
CSI
E
nclosure
S
ervices, one of the enclosure management standards.
“SES config”
can enable or disable the management of SES.
40
Advanced operation