background image

3/20 

 

DANGER 

Do not service the Controller in the Power-ON status. To avoid an electric shock, be sure to turn 

OFF the power supply before starting the service. 

Do not disassemble, remodel or repair the Controller, or an electric shock, a fire or injury could be 

caused. For repair, ask the dealer. 

Do not remove the front cover while the Controller is in the Power-ON status, or an electric 

shock could be caused. 

Do not put or insert anything in or into the Controller, or an electric shock or a fire could be 

caused. 

Do not use the Controller near explosive or flammable gas, or a fire could be caused. 

Do not splash water or liquid, or an electric shock or a fire could be caused. 

If  smoke,  odor  or  abnormal  noise  is  emitted  or  other  abnormality  is  detected,  shut  down  the 

Controller immediately. If the Controller is used in the abnormal status, a fire could be caused. 
Contact the dealer. 

If the Controller is not operated for a long time, shut down the Controller. If the Controller is left 

live as it is, a fire could be caused. 

Connect the power cable and the output cable as instructed in the Manual to avoid an electric 

shock and a fire. 

Do not forcedly bend, pull or pinch the power cable or the output cable, or an electric shock or a 

fire could be caused. 

Ground the earth terminal and the ground prescribed portions without fail, or an electric shock 

could be caused. When working on grounding to a high position or a shaky stand, because fall or 
tumble could be caused conditionally, take measures to prevent fall or tumble. 

Do not conduct megger testing for any terminals other than the input terminal.

 

 

CAUTION   

Do not use the Controller for an electromagnetic parts feeder or the like. 

Do not turn ON/OFF the power supply frequently, or failure could be caused. 

Do not start/stop the vibrator with an electromagnetic contactor or the like on the output side, 

  or failure could be caused. 

Do not perform welding work on the feeder side in the Power-ON status. 

Do not perform welding work on the feeder side when the feeder and the Controller are in the 

  connected status. 

Do not remove the nameplate, the seal, or the like. 

When installing the Controller, hold and fix it firmly and properly. 

Do not transport or carry the Controller in the piled-up status, even in the packed status, or they 

  could fall, causing injury. 

Do not place the Controller outdoors, in a humid place or in a place with excessive temperature 

  change. 

Do not pile up the Controller two-tired or more, even in the packed status. 

When disposing of the Controller, dispose it properly as general industrial waste.

 

 

 

Содержание P212

Страница 1: ...ntroller version 2 and later Confirm the version information displayed upon powering ON Ver 2 Read the Manual carefully beforehand to ensure the safe use of the Controller After reading store the Manu...

Страница 2: ......

Страница 3: ...n of Operation Panel 7 2 Displayed Mode 7 3 Setting the Frequency Lock 7 4 Preparation for Operation Operation and Amplitude Adjustment Method Added Function 10 Initialization of the Set Data 11 Remot...

Страница 4: ...the packing Unpack and check the following 1 Isn t there any damage caused during transport 2 Are the rating capacity and model on the nameplate exactly what you have ordered If there is any problem...

Страница 5: ...e or the output cable or an electric shock or a fire could be caused Ground the earth terminal and the ground prescribed portions without fail or an electric shock could be caused When working on grou...

Страница 6: ...cable 1m Operation panel Rubber bush Relay connector Operation panel fixing screw 2 locations Earth Operation panel connecting wire Operation panel When attaching detaching the operation panel carefu...

Страница 7: ...flat blade screwdriver or similar insert the wire into the wire insertion hole Then detach the flat blade screwdriver to release the button and the wire will be fixed Applicable wire size Stranded wir...

Страница 8: ...es Connect the external I O signals Amplitude adjustment Adjust the amplitude to optimize the work transfer speed Outputs the setting output voltage frequency for a certain length of time Set the outp...

Страница 9: ...nnect any feeder other than the piezo feeder made by Sanki 2 Do not operate with no load 3 Be sure to ground the feeder 2 Power source connection Connect the power cable to the single phase power sour...

Страница 10: ...f the controller according to external control signal either method of non voltage contact signal or voltage signal 24VDC can be used Make connection to the external control terminal block by using th...

Страница 11: ...sed briefly when the voltage is being displayed the voltage display switches to the frequency display Frequency lock setting display Changes the frequency lock setting Parameter mode Changes the param...

Страница 12: ...ays the current setting When the Func key is pressed again the voltage is displayed Voltage Frequency F LOCK Voltage To select the setting press the Freq key or Freq key To execute the setting change...

Страница 13: ...control is OFF Quick blinking In forced operation Slow blinking Forced operation at a stop Forced operation means Forcedly starting stopping the operation by pressing the ON OFF button whether the op...

Страница 14: ...screen to the frequency setting screen Switches the frequency setting screen to the output setting screen Vol keys Lowers the output until the speed is lowered to the speed at which the parts moves s...

Страница 15: ...ialization of the Set Data Returning to the factory setting 1 When the Controller is in the Power OFF status power ON the Controller by pressing the Vol key and the Freq key together The Controller st...

Страница 16: ...iable voltage input 3 contacts No voltage contact input 2 Connection Connect the remote unit to the terminal block of the main unit of the Controller Px12 3 Usage 1 Set the remote unit to valid Parame...

Страница 17: ...hout pressing the Set key in the change process the changes will not be saved but cancelled If there is no key operation for over 5 min the normal mode screen voltage display will be forced to reappea...

Страница 18: ...y Reset the error by either of the following methods 1 and 2 When resetting the error eliminate the abnormality beforehand If the external signal is an operation condition be careful that the Controll...

Страница 19: ...lock The overcurrent error E 01 is displayed The feeder is probably abnormal Contact the dealer Ground fault was caused due to damage to the controller output cable cover or the feeder wire cover Repl...

Страница 20: ...or 24VDC Others Soft start soft stop short circuit protection etc Power outlet 24VDC 160mA Operating temperature range 0 40 Operating humidity range 30 90 no condensation Place of use Indoor no corro...

Страница 21: ...19 20 17 Outside Dimensional Drawing The input and output cables are omitted...

Страница 22: ...y a fire an earthquake a flood or the like or unspecified power source voltage frequency Failure caused by improper handling or operation Failure caused by handling against the usage specifications or...

Страница 23: ......

Страница 24: ...ai Office Tel 81 22 263 8345 Fax 81 22 263 8354 Tokyo Office Tel 81 3 3493 6187 Fax 81 3 3493 6195 Nagoya Office Tel 81 52 691 1147 Fax 81 52 692 1915 Osaka Office Tel 81 6 6746 8222 Fax 81 6 6746 822...

Отзывы: