13/20
9. Added Function
Soft start and soft stop functions
If the rising time or falling time of the piezo feeder should be adjusted, change the settings of
the soft start or soft stop.
To change the settings, set the relevant parameter accordingly.
Parameter No. 0C: Soft start = The time until the set output is achieved after the operation
starts
Parameter No. 0d
:
Soft stop = The time until the stop is made from the set output after the
stop conditions are met.
The set time is 0.2
-
9.9 sec. (The default value is invalid.)
10. Initialization of the Set Data
【
Returning to the factory setting
】
(1)
When the Controller is in the Power-OFF status, power ON the Controller by pressing the
Vol
▲
key and the Freq
▼
key together. The Controller starts in the initialization mode,
and the data display shows “99” in blinking.
(2)
In this status, press the Func key and the Set key together long for over 3 sec. All set data
are reset.
(3)
Upon the completion of resetting, the data display shows “99” in lighting.
(4)
When the Func key is pressed long for over 2 sec, the Controller starts in the factory setting
status.
So is the case with powering OFF and then powering ON the Controller.
※
When the above procedure is taken, all set data of parameter, frequency and voltage are
cleared.