7. Explanation of Operation Panel

 

7-1. Explanation of Operation Panel

 

 

 

 

 

 

 

1) Pilot lamps

 

 

 

 

 

 

 

 

 

 

 

 
 

 

 

 

 

 

 

 

 

 

2) Operation keys 

No 

Name 

Function 

ON/OFF key  Performs the forced operation and the forced stopping. 

Func key 

Brief pressing: Switches the frequency lock setting.

 

Long pressing: Switches the mode between the parameter mode and the   

normal mode. 

Set key 

Brief pressing: Changes and locks the data.

 

Vol 

  key 

Normal mode: Adjusts the output voltage.

 

When pressed briefly when the frequency is being displayed,   
the frequency display switches to the voltage display. 

Parameter mode: Selects the parameter No. 

Vol 

  key 

Freq 

  key  Normal mode: Adjusts the frequency.

 

            

When pressed briefly when the voltage is being displayed,   
the voltage display switches to the frequency display.

 

Frequency lock setting display: Changes the frequency lock setting. 
Parameter mode: Changes the parameter data.

 

Freq 

  key 

No 

Name 

Function 

 

Data display 

A 7-segment, 4-digit LED 
Displays voltage, frequency, 
each settings and error 
codes.

 

 

Frequency pilot 
lamp 

ON when the data display 
is showing frequency

 

 

Voltage % pilot 
lamp 

ON when the data display 
is showing voltage

 

 

Operation pilot 
lamp 

Indicates the output 
condition of the controller. 
ON: The Controller is in 
operation under external 
control. 
Blinking: The Controller is in 
forced operation by the 
ON/OFF key. 
Long OFF and blinking: The 
Controller is at a forced 
stop by the ON/OFF key.

 

 

Parameter 
mode pilot lamp 

ON  when  the  parameter 
is being set

 

 

Frequency lock 
pilot lamp 

ON when the frequency is 
locked.

 

Содержание P212

Страница 1: ...ntroller version 2 and later Confirm the version information displayed upon powering ON Ver 2 Read the Manual carefully beforehand to ensure the safe use of the Controller After reading store the Manu...

Страница 2: ......

Страница 3: ...n of Operation Panel 7 2 Displayed Mode 7 3 Setting the Frequency Lock 7 4 Preparation for Operation Operation and Amplitude Adjustment Method Added Function 10 Initialization of the Set Data 11 Remot...

Страница 4: ...the packing Unpack and check the following 1 Isn t there any damage caused during transport 2 Are the rating capacity and model on the nameplate exactly what you have ordered If there is any problem...

Страница 5: ...e or the output cable or an electric shock or a fire could be caused Ground the earth terminal and the ground prescribed portions without fail or an electric shock could be caused When working on grou...

Страница 6: ...cable 1m Operation panel Rubber bush Relay connector Operation panel fixing screw 2 locations Earth Operation panel connecting wire Operation panel When attaching detaching the operation panel carefu...

Страница 7: ...flat blade screwdriver or similar insert the wire into the wire insertion hole Then detach the flat blade screwdriver to release the button and the wire will be fixed Applicable wire size Stranded wir...

Страница 8: ...es Connect the external I O signals Amplitude adjustment Adjust the amplitude to optimize the work transfer speed Outputs the setting output voltage frequency for a certain length of time Set the outp...

Страница 9: ...nnect any feeder other than the piezo feeder made by Sanki 2 Do not operate with no load 3 Be sure to ground the feeder 2 Power source connection Connect the power cable to the single phase power sour...

Страница 10: ...f the controller according to external control signal either method of non voltage contact signal or voltage signal 24VDC can be used Make connection to the external control terminal block by using th...

Страница 11: ...sed briefly when the voltage is being displayed the voltage display switches to the frequency display Frequency lock setting display Changes the frequency lock setting Parameter mode Changes the param...

Страница 12: ...ays the current setting When the Func key is pressed again the voltage is displayed Voltage Frequency F LOCK Voltage To select the setting press the Freq key or Freq key To execute the setting change...

Страница 13: ...control is OFF Quick blinking In forced operation Slow blinking Forced operation at a stop Forced operation means Forcedly starting stopping the operation by pressing the ON OFF button whether the op...

Страница 14: ...screen to the frequency setting screen Switches the frequency setting screen to the output setting screen Vol keys Lowers the output until the speed is lowered to the speed at which the parts moves s...

Страница 15: ...ialization of the Set Data Returning to the factory setting 1 When the Controller is in the Power OFF status power ON the Controller by pressing the Vol key and the Freq key together The Controller st...

Страница 16: ...iable voltage input 3 contacts No voltage contact input 2 Connection Connect the remote unit to the terminal block of the main unit of the Controller Px12 3 Usage 1 Set the remote unit to valid Parame...

Страница 17: ...hout pressing the Set key in the change process the changes will not be saved but cancelled If there is no key operation for over 5 min the normal mode screen voltage display will be forced to reappea...

Страница 18: ...y Reset the error by either of the following methods 1 and 2 When resetting the error eliminate the abnormality beforehand If the external signal is an operation condition be careful that the Controll...

Страница 19: ...lock The overcurrent error E 01 is displayed The feeder is probably abnormal Contact the dealer Ground fault was caused due to damage to the controller output cable cover or the feeder wire cover Repl...

Страница 20: ...or 24VDC Others Soft start soft stop short circuit protection etc Power outlet 24VDC 160mA Operating temperature range 0 40 Operating humidity range 30 90 no condensation Place of use Indoor no corro...

Страница 21: ...19 20 17 Outside Dimensional Drawing The input and output cables are omitted...

Страница 22: ...y a fire an earthquake a flood or the like or unspecified power source voltage frequency Failure caused by improper handling or operation Failure caused by handling against the usage specifications or...

Страница 23: ......

Страница 24: ...ai Office Tel 81 22 263 8345 Fax 81 22 263 8354 Tokyo Office Tel 81 3 3493 6187 Fax 81 3 3493 6195 Nagoya Office Tel 81 52 691 1147 Fax 81 52 692 1915 Osaka Office Tel 81 6 6746 8222 Fax 81 6 6746 822...

Отзывы: