10/20
7-2. Display Mode
1) Normal mode
Displays and sets the output voltage, frequency and frequency lock setting on the data display
area.
Upon turning ON the power supply, this display appears.
2) Parameter mode (Pilot lamp
⑤
FUNC lights up.)
Shows and sets the parameter on the data display.(Details
⇒
P.15)
To switch the display mode, press the Func key long for 2 sec.
Regardless of the display mode, operation and stopping through the panel and under the external
control is enabled.
7-3.
Setting the Frequency Lock
This setting is enabled when the normal mode (output voltage, frequency) is in display. When the
Func key is pressed, the pilot lamp
⑥
F-LOCK starts blinking, and the data display area displays
the current setting.
When the Func key is pressed again, the voltage is displayed.
Voltage (Frequency)
→
⑥
F-LOCK
→
Voltage
To select the setting, press the Freq
▲
key or Freq
▼
key. To execute the setting
change, press the Set key.
When the setting change is completed, the voltage is displayed.
If the process is brought forward to the next item by pressing the Func key without
pressing the Set key during the setting change, the setting will not be changed.
※
If there is no key operation for over 5 min, the voltage is displayed.
on : The frequency cannot be changed.
oFF: The frequency can be changed.
7-4.
Preparation for Operation
Before powering ON the Controller, recheck the model, specifications and power voltage of the
Controller to confirm no discrepancy, and also recheck the connections to confirm no wrong
connection. Particularly when external signal is used, be careful not to mistake the polarity.