14. Troubleshooting
Trouble
Probable cause
Corrective action
The feeder does not vibrate.
The power cable is not connected.
Connect the power cable.
“Voltage (%)” is “0.0.”
Set “Voltage(%).”
The set frequency is wrong.
Adjust the frequency to the
resonance frequency.
The output connectors is disconnected
from the feeder.
Connect the output connector to
the feeder.
The RUN lamp is OFF.
Check the external control.
Check the parameter settings.
The RUN lamp is blinking.
Press the ON/OFF key
The frequency cannot be
adjusted.
The F-LOCK lamp is ON.
Release the lock.
The overcurrent error (E-01)
is displayed.
The feeder is probably abnormal.
Contact the dealer.
Ground fault was caused due to damage
to the controller output cable cover or
the feeder wire cover.
Replace the damaged cable or wire.
The frequency is deviant.
Adjust the frequency to the
resonance frequency.
One of the memory errors
(E-10
–
12) occurs when the
Controller starts.
There was a memory error when the
power supply was turned ON.
Reset the power supply.
If the same error recurs, contact
our sales agent for consultation.
15. Options
Name
Applied wire
Length (mm)
Terminal
Remarks
Power cable
VCTF 0.75x3
1200
Nichifu pin terminal male
PC-2005M
Mounting as
standard
Output cable
VCTFK 0.75x2
1200
Molex terminal
1189ATL
Molex housing 3P
1396R1