12 S&C Instruction Sheet 1041-540
Installation
Categories
Fields
1 . Real-
Time Data
2 . Auto Operation
3 . Sw . 2 Auto
Operation
4 . Fault
Events
5 . Fault
Magnitude
6 .
Maintenance
7 . Fault
Settings
Cloose/Open
Status
[Sw . 1, 2, 3]
Operations
Counter
[Sw . 1, 2, 3]
Switch 1 Line
Current (Amps)
Switch 2 Line
Current (Amps)
Switch 3 Line
Current (Amps)
Ground Current
(Amps)
[Sw . 1, 2, 3]
Switch 1 Line
Voltage (Volts)
Switch 2 Line
Voltage (Volts)
Switch 1 Phase
Angle (Degrees)
Switch 2 Phase
Angle (Degrees)
Switch 1 Reverse
Current (Active or
None)
Switch 2 Reverse
Current (Active or
None)
Switch 1 Line
kVARs Switch 2
Automatic
Operation Features
Enabled
Transfer Process
Time Limit
Return to Normal
Delay Time
Sectionalizer Reset
+ Extended Voltage
Loss Time
Successful Reclose
Rest Time
Fault Current
before First/All
Voltage Loss(es)
Recloser Counts to
Trip, w/Fault
Recloser Counts to
Trip, Voltage loss
Only
Number of Shots
Required for
Lockout
Shots-To-Lockout
Time Threshold
(Tenths)
Phase Loss
Protection Voltage
Loss Threshold
Phase Loss
Protection Time
Threshold
Phase Loss
Protection Current
Threshold
Automatic Reclose
Time Threshold
Present Transfer
Capacity, Left
Feeder
Present Transfer
Capacity, Right
Feeder
Automatic
Operation Features
Enabled
Transfer Process
Time Limit
Return to Normal
Delay Time
Sectionalizer
Reset + Extended
Voltage
Loss Time
Successful
Reclose
Rest Time
Fault Current
before First/All
Voltage Loss(es)
Recloser Counts to
Trip, w/Fault
Recloser Counts to
Trip, Voltage loss
Only
Number of Shots
Required for
Lockout
Shots-To-Lockout
Time Threshold
(Tenths)
Phase Loss
Protection Voltage
Loss Threshold
Phase Loss
Protection Time
Threshold
Phase Loss
Protection Current
Threshold
Automatic Reclose
Time Threshold
Present Transfer
Capacity, Left
Feeder
Present Transfer
Capacity, Right
Feeder
Software
Version
AC Power/
Battery
Status
Battery
Low/Bad
Setpoints
Battery
Voltage w/o
Surface
Charge
Predicted
Voltage
Under Load
Power
Supply
Voltage/
Battery
Impedance
Cabinet
Temperature
Phase Fault
Detected
Current Level
(Amps) [Sw .
1, 2]
Ground Fault
Detected
Current Level
(Amps)
[Sw . 1, 2]
Phase Fault
Duration Time
Threshold
(msec)
[Sw . 1, 2]
Ground Fault
Duration Time
Threshold
(msec)
[Sw . 1, 2]
Phase
Current
Inrush
Restraint
Time (msec)
[Sw . 1, 2]
Ground
Current
Inrush
Restraint
Time (msec)
[Sw . 1, 2]
Phase
Current
Inrush
Restraint
Multiplier
[Sw . 1, 2]
Ground
Current
Inrush
Restraint
Multiplier
[Sw . 1, 2]
Figure 4. LCD screen data page for 5802/5803 controls.