33
6.6.7. STC-H SET (Sea Clutter Set)
Adjust distance for removal sea reflection to
identify targets marked as small spots.
(In a transmitting)
Set it to Max.
Set it to Minimum
Set it to Max.
Set it to 6NM for distance range
Menu screen
Move to
INIT. SET
Push bottons one after another,
It is displayed additional menu
out of default(settion) menu.
Move to
STC-H SET
,
Select, PPI screen comes up and
displayed number in the
middle
of
top screen.
Adjust to disapper noise to 6NM.
(Adjust to have little noise in a ring
of 6NM)
[ Ref. ]
☞
Adjust Range : 000 ~ 255
:
1 Step Adjust
: 10 Step Adjust
If the values are set with too high, the targets are
hided by STC-H function and, if with too low, it may
be difficult to identify targets as showing targets /
sea reflection together.
Set by adjusted value which has
been completed.
Return to ordinary PPI screen.
6
1
143
CAUTION
※
The adjust was set when it is supplied
from a manufacturer and if adjusted
unnecessarily, the error may be taken
place.