WEA453e Installation Manual
Version 1.0
Samsung Electronics America
Page
39
of
117
2.4.2
Mounting to a Pole
Mounting the Outdoor AP to a Pole
1) Prepare the following components:
Table 13.
Components and Tools for Mounting the Outdoor AP
Item
Description
Components
Mount Bracket
1 EA
Tightening
Components
Metal Bands
2 EA
M4 Torx Screws (WSP)
3 EA
Regulated Torque Value
M4 × L14 Torx Screw
9.52-14.28 kgf·cm
Required Tool
Torque Driver (T20H)
The metal band used for attaching the mount bracket to the pole must be made
from an approved material and the screws should be stainless steel (STS 304).
If these regulations are not followed, the components can become corroded and
rust.
The 2 M4 Torx Screws (WSP) should be tightened on the left and right sides of
the bracket.
2) Attach the mount bracket to the pole using the metal bands.
Figure 21.
Mounting the Outdoor AP on a Pole (1)
Mount Bracket
Metal band
Pole