Item
Main Inspection
Checklist
Evaluation Criteria
Inspection
Results
Pass
Fail
materials used.
Cable connection
status
Check the power connection status for
each cable according to the pin map
configuration.
Check the pressure terminal/connector's
assembly and tightened status to
determine if the tightening torque value
has been met.
Cable tag installation
status
Check the location, labeling, and tag
installation method used.
RF
Antenna installation
status
Check the specifications, installation
position, mounting status, and gap
between each antenna.
Arrestor installation
status
Check the specifications, installation
position, and mounting status.
Cable installation and
binding status
Check the damage/installed route/
bending radius of cables and the
materials used.
Cable connection
status
Check the cable connection status, the
connector assembly, and the tightened
state.
Check if the tightening torque value has
been met.
Check the finishing status.
Cable tag installation
status
Check the location, labeling, and tag
installation method used.
Miscellane
ous
Reserved ports and
cable connection
status
Check the finishing status (waterproof
caps, etc.).
Equipment connection
I/O port (conduit/cable
gland)
Check the tightened status.
Cable installation route
status
Check the status of the cable tray, duct,
and other installation items.
Clean-up state for
inside/outside and the
surrounding area of
the system.
Check for any disposed materials/items/
packing materials and the overall clean-
up status.
Opinions