3.4 Connecting a Power Cable
The power system consists of the following configuration:
Figure 41.
Power Supply Configuration
When handling power cables, ensure the power switch of the rectifier, and/or the
system, is turned off to prevent short circuits and electrical accidents.
An electrical accident can occur if fasteners become loose. Make sure the
fasteners that secure the power cable are firmly attached. Use a power cable that
has a temperature limit of 90°C or higher.
Make sure to consider the allowable curvature radius of a cable before you install
or cut the cable. If you cut a cable without considering its curvature radius, a
contact failure can occur after the cable is connected.
Connecting a Power Cable
1) Prepare the following components:
Table 20.
Components and Tools for Connecting a Power Cable
Item
Description
Installation
Section
Rectifier-Outdoor AP Power Input Terminal
Cables
AC Distribution Box-
AC/DC Adaptor
Power Cable Assembly-1 (100-240VAC)
AC/DC Adaptor-Outdoor
AP Power Input Terminal
Power Cable Assembly-2 (48 VDC)
Connectors
AC Distribution Box
Check the output port standards for the field and
prepare the connector.
Outdoor AP
-
System Side: DY5F1203PNFL[JONHON]
-
Cable Side: DY5T1203SNF[JONHON]
Required Tools
Cable Cutter, Wire Stripper, Crimper, Heating Gun, Torque Driver (+), Torque
Wrench, and Nipper
AC Distribution
Box
Commercial
Power
AC
DC
System
AC/DC Adaptor