WEA453e Installation Manual
Version 1.0
Samsung Electronics America
Page
55
of
117
Item
Description
Fastening Components MGB
Check the MGB standards for the field and have the
fasteners ready.
Outdoor AP
M6 × 12L SEMS/2 EA (tightened to the system)
Regulated Torque
Value
M6 SEMS
33.28~49.92 kgf·cm
Required Tools
Cable Cutter, Wire Stripper, Crimper, Heating Gun, Torque Driver (+),
Torque Wrench, and Nipper
2) Install a ground cable from the MGB to the ground terminal of the Outdoor AP.
Figure 34.
Connecting a Ground Cable to the Outdoor AP (1)
3) After assembling a pressure terminal with a heat shrink tube, secure it firmly into the
ground terminal of the system using the M6 SEMS.
Fastening components, such as the pressure terminal or cables, must meet the
UL or equivalent standards requirements.
Ex) Manufacturer: Panduit
Outdoor AP: 4 mm
2
Pressure Terminal (LCD10-14A-L)
For information on how to assemble the pressure terminal and the heat shrink
tube, see ANNEX C.
Ground Cable
MGB