11
/
66
5. Angle lock: cooperate with the left and right locks of the cabinets, fast connect and
lock the adjacent cabinets for flat or curve connection;
6. Test button: used during testing;
7. Safety lock----protect the power box;
8. Module----Product display module;
9. Locking lever on the cabinet----Locking the cabinet;
10. Safety rope----Hang the module and protect the module;
11. The left and right locks of the cabinet----with the angle lock, quick connection and
locking the adjacent cabinets for the flat or curve connection;
12. Automatic locking piece----With the locking lever, quick connection and locking the
adjacent cabinet;
Remark:
The module housing in the Picture is applicable to VMR-O P3.9
Main power cable:
Power supply to the display, the wire diameter is 3*2.5mm
²
, and the maximum load
current is 16A, as shown in Picture 5-2. In the Picture, 1 is the aviation head
connected to the cabinet, and 2 is the mains plug. (We will provide different plugs
according to different countries).
Picture 5-2 Main Power Supply Cord
Main signal cable:
Connect the sending box and the display screen. The super five types of network
cables are usually 30m in length and 70m in length, as shown in Picture 5-3.
Содержание VMR-O P3.9
Страница 1: ...1 66 Product Manual VMR O P3 9 ...
Страница 34: ...34 66 Appendix A Dimensional Drawing of Main Components A 1 VMR O VMR O P3 9 Flat Panel Curve Panel A 2 Flykit ...
Страница 41: ...41 66 C 5 Plastic hammer ...
Страница 49: ...49 66 ...
Страница 53: ...53 66 F8 Press the lock handle according to the mark to lock the cabinet as shown below ...
Страница 55: ...55 66 G4 Open the back cover of the power supply cabinet as shown below as shown below ...