Caution when Installing the RF antenna
To protect from lightning, the RF antenna must be installed within the shielding
angle as shown below, considering the downward distance and the angle from
the tower lightning rod or the antenna pole lightning rod.
- The protection angle of the lightning rod should be 45 degrees.
Finishing Heat Shrink Tube of a Sector Antenna
1) Insert an antenna protection plate.
2) Place the heat shrink tube on the connection point and shrink the heat shrink
tube using a heat gun.
3) Avoid aiming the heating gun toward the antenna’s body as shown in the figure
below.
Lightning rod
45
°
45
°
RF Antenna
Heat Shrink Tube
(Jelly Type)
Antenna Jumper Cable
(1/2 in. Feeder Line)
Heat Shrink Tube
(Jelly Type)
Antenna Protection Plate
Antenna Protection Plate