Smart MBS RRH-P4 Installation Manual/Ver.2.0
© SAMSUNG Electronics Co., Ltd.
2-17
2.6 Connecting ground cable
2.6.1 Grounding RRH-C2A
Follow the steps below to connect the RRH-C2A ground cable.
1) Install one ground cable (AWG8, GV 6 mm
2
× 1 C) from MGB to the ground terminal
at the bottom of RRH-C2A.
2) Install the 6 mm
2
pressure terminal and the heat shrink tube at the end of the cable.
3) Place the pressure terminal at one end of the ground cable of RRH-C2A aligning with
the fixing holes and fix it using M6 SEMS.
(When being secured by screw, apply 38.16~46.64 kgf.cm torque.)
Figure 2.12 Connecting RRH-C2A Ground cable
M6 x 12L SEMS
Ground Cable(AWG8, GV 6 mm
2
× 1C)
From MGB(Main Ground Bar)
Detail ‘A’
Heat Shrink Tube(Green)
6 mm
2
Pressure Terminal
(2Hole, 90°, Hole diameter: 6.3 mm,
Hole distance: 16 mm)
RRH-C2A
‘A’