CHAPTER 2. Installation of RRH-C2A
2-38
© SAMSUNG Electronics Co., Ltd.
RRH-C2A Optic Cable
The optic cable consists of 5 cores. The grey cable is the spare cable for
replacement in case one of the 4-core optic cables would fail.
2.7.5 Remaining length of Hybrid cable
Follow the steps below to organize the remaining length of the cable after connecting the
hybrid cable (power cable, CPRI cable) to RRH-C2A.
1) Loop the excess length of the power cable and CPRI cable, and attach to the RRH-
C2A fixing pole using a cable tie. Ensure to respect the optic cable’s bending radius of
(R=110 mm).
2) Bind the power cable and CPRI cable together with the feeder line using a cable tie.
Figure 2.36 Remaining length of Hybrid cable (1)
Cable Tie
Feeder Line
RRH-C2A
RRH-C2A Fixing Pole
Remaining length of cable
Cable Tie