4. Troubleshooting
4.7.8. Incorrect color registration
A. Typical faulty images
B. Troubleshooting procedure
Step
Cause
Action
1
ACR execution is needed.
Execute ACR manually.
(Refer to 4.5.5.6.)
2
ACR sensor is contaminated.
Clean the ACR sensor.
(Refer to 3.2.1.1.)
3
Circumstances is changed.
To recognize the eviroment chage, execute ACR
after a certain amount of time.
(Refer to 4.5.5.6.)
4
Check if the skew is occurs at the cassette or feeding rollers.
Adjust the skew manually.
(Refer to 4.7.)
5
Belt surface is contaminated.
Remove the ITB. If the surface of the belt is
contaminated, clean it with soft cloth.