4. Troubleshooting
► Error Code
A2–1211 / A2–1212 / A2–1221 / A2–1223
A2–1521 / A2–1523
A2–2310 / A2–2311 / A2–2321 / A2–2323
► Error message
Fan Failure: #A2–1211 / A2–1212 / A2–1221 / A2–1223. Turn off then on. Call for service if the problem persists
Fan Failure: #A2–1521 / A2–1523. Turn off then on. Call for service if the problem persists
Fan Failure: #A2–2310 / A2–2311 / A2–2321 / A2–2323. Turn off then on. Call for service if the problem persists
► Symptom
SMPS or Fuser or Duplex or LSU fan is not operational.
► Troubleshooting method
NOTE
•
SMPS fan error : A2–1211 / A2–1212 / A2–1221 / A2–1223
•
Duplex fan error : A2–1521 / A2–1523
•
Fuser fan error : A2–2310 / A2–2311 / A2–2321 / A2–2323
1) Turn the machine off.
2) Remove the rear cover.
(
Refer to 3.3.2 Rear Cover in chapter 3
)
3) Check if the corresponding fan connector is connected correctly.
4) If the connection is OK, Enter SVC mode and execute fan test.
(Diagnostics > Engine Diagnostics > Engine Test Routines)
•
100-0260 : SMPS Fan Run
•
109-0040 : Fuser Fan Run
Copyright© 1995-2017 SAMSUNG. All rights reserved.